7.4
Commissioning linear actuators
7.4.1
Preparing linear actuators for commissioning
Requirements
You have already installed the positioner using the suitable mounting kit.
Setting the transmission ratio selector
Note
Commissioning
The setting of the transmission ratio selector is extremely important to commission the
positioner.
Stroke [mm]
1. Move the carrier pin on the lever. Select the scale position equal to the nominal stroke or
2. Tighten the carrier pin using the M6 hexagon nut.
Connecting the positioner
1. Connect a suitable current or voltage source. The positioner is now in the "P manual
2. Connect the actuator and the positioner to the pneumatic lines.
3. Supply the pneumatic auxiliary power to the positioner.
SIPART PS2 with and without HART
Operating Instructions, 10/2013, A5E00074631-11
Lever
5 ... 20
Short
15 ... 35
Short
30 ... 130
Long
a next-higher position.
mode". The current potentiometer voltage (P) in percent is shown in the upper line of the
display, e.g.: "P12.3", and "NOINI" blinks in the lower line:
7.4 Commissioning linear actuators
Position of the transmission ratio selector
In [°]
33
90
90
Commissioning
Position
Down
Up
Up
123