Emerson Rosemount 2120 Reference Manual page 48

Level switch, vibrating fork
Hide thumbs Also See for Rosemount 2120:
Table of Contents
Reference Manual
00809-0100-4030, Rev FA
Figure A-7. Tri Clamp Mounting (Extended Length, Surface Finish Codes 1 and 2)
Glass-filled nylon housing
(and not hygienically approved)
Allow 1.2 (30)
to remove cover
5.2
(132)
Ø1.6 (41)
E(M)
1.7
(44)
0.5 (13) switchpoint
(when mounted horizontally)
1
A. Cable entry M20 x 1.5 or
/
-in. ANPT
2
3
B. Cable entry M20 x 1.5 or
/
-in. ANPT
4
Dimensions are in inches (millimeters).
Table A-5. Fork Length for Tri Clamp Rosemount 2120 (Not Hygienically Approved)
Process
connection
Tri Clamp
(surface finish code 1)
Tri Clamp
(surface finish code 2)
42
4 (102)
3.5 (90)
C
Ø1.1 (28)
0.5 (13) switchpoint
(when mounted vertically)
Standard length
fork length code A
1.7 in. (44 mm)
1.7 in. (44 mm)
Aluminum/stainless steel housing
(and not hygienically approved)
Allow 1.2 (30)
to remove cover
A
6.4
(162)
Ø1.6 (41)
E(M)
0.5 (13) switchpoint
(when mounted horizontally)
1
C. 1
/
-in. (38 mm) or 2-in. (51 mm) Tri Clamp, surface finish codes 1 and 2
2
Minimum length
fork length code E (M)
4.13 in. (105 mm)
4.13 in. (105 mm)
Specifications and Reference Data
4.7 (120)
C
Ø1.1 (28)
1.7
0.5 (13) switchpoint
(44)
(when mounted vertically)
Maximum length
fork length code E (M)
157.5 in. (4000 mm)
157.5 in. (1000 mm)
Specifications and Reference Data
December 2016
B

Hide quick links:

Table of Contents
loading

Table of Contents