beautypg.com
Manuals
Brands
Emerson Manuals
Switch
200I/48-NT5C05C
Emerson 200I/48-NT5C05C Manuals
Manuals and User Guides for Emerson 200I/48-NT5C05C. We have
1
Emerson 200I/48-NT5C05C manual available for free PDF download: Installation And User Manual
Emerson 200I/48-NT5C05C Installation And User Manual (62 pages)
Helios Modular Switch Mode Rectifier 200I/48
Brand:
Emerson
| Category:
Switch
| Size: 0.34 MB
Table of Contents
Table of Contents
7
1 General Information
11
Purpose of this Manual
11
Figure 1 - Front View of the Modular 200I / 48 Switch Mode Rectifier
11
Models and Mounting Configurations
12
Figure 2 - Typical Mounting in a Cabinet or Frame
12
2 Specifications
13
Mechanical and Electrical Specifications
13
Table 1 - Mechanical Specifications of the Rectifier
13
Table 2 - Electrical Specifications of the Rectifier
13
Operation Specifications and Ambient Conditions
14
Table 3 - Operation Specifications of the Rectifier
14
Table 4 - Ambient Conditions for the Rectifier
15
Mechanical and Electrical Specifications of a 1200 a Cabinet
16
Ambient Conditions of a 1200 a Cabinet
16
Table 5 - Mechanical Specifications of the NT6C43CB 1200 a Cabinet
16
Table 6 - Electrical Specifications of the NT6C43CB
16
Table 7 - Ambient Conditions for the NT6C43CB 1200 a Cabinet
16
3 Installation
17
Mounting Configurations
17
Tools and Test Equipment
17
Cautions and Warnings
17
Installing in a Frame
20
Installing in a Cabinet
20
Procedure 1 - Installing the Rectifier in a Frame
20
Figure 3 - Anchoring the Cabinet
21
Procedure 2 - Installing a Rectifier in a Cabinet
21
Cabling and Connecting
22
Figure 4 - Installing the Rectifier
22
Connecting the DC Output Terminals to the Busbars
23
Figure 5 - Connecting the DC to the Busbars with a Shunt on the Battery Side or a Shunt on the Ground Side
23
Running and Connecting the DC between Busbars and a Rectifier
24
Securing the DC Output Terminals to the Busbars in a 1200 a Cabinet
24
Connecting Ac to the Rectifiers
24
Procedure 3 - Securing the DC Output Terminals to the Busbars of the Cabinet
24
Procedure 4 - Typical DC Cabling in a Frame Application
24
Procedure 5 - Cabling the Ac Input to the NT5C05CA / CB Rectifiers
25
Figure 6 - Cabling Ac the NT5C05CA / CB Rectifiers
26
Figure 7 - Connect the Power Leads to the L1, L2 and L3 Terminals of the Rectifier
26
Figure 8 - Connecting Ac to the Rectifier NT5C05CC
27
Procedure 6 - Connecting the Ac Male Plug between the NT5C05CC Rectifier
27
And the Ac Female Plug in a 1200 a Cabinet
27
Connecting the Control Signals
28
Rectifier
28
Figure 9 - Typical Connections between Rectifiers and the Conventional Controller
28
Procedure 7 - Connecting the NT5C05CC to the Controller
28
Monitoring of the Shunt Current
29
Table 8 - Pin Assignment for Connectors J7 to J12
29
Procedure 8 - Connecting an NT5C05CC Rectifier Directly to a Controller
29
Table 9 - Pin Assignment for Connector J13
30
4 Functional Description
31
Overview
31
Input Circuit
31
Output Circuit
31
Monitoring and Control Circuits
32
Output Capacitors
32
Description of the Front Panel
32
Breakers
32
Switches, Controls and Leds
33
Figure 10 - Front Panel Controls and Leds
33
Front Panel Leds
34
Table 10 - Designation of the Leds on the Front Panel
34
Local and Remote Adjustments and Controls
35
Voltage / Current Display Test and Measurement
36
Table 11 - Adjusting the Potentiometers and Switches
36
Table 12 - Rectifier Input / Output Signals to the Controller
36
Float and Equalize Voltage Control
37
Current Limit Adjustment and Rectifier Regulating Test
37
Rectifier Parallel Operation
38
HVSD ( High Voltage Shutdown )
40
TR ( Temporary Inhibition ) and Sequential Start
40
Table 13 - Setting the Start-Up Delay
41
Control Signals on Connector P1
42
Table 14 - Control Signal Connections on P1
42
5 Operation
45
Standard Settings
45
Table 15 - Standard Settings for the Rectifier
45
Starting up and Adjusting
46
Procedure 9 - Starting up the Rectifier
46
6 Maintenance
49
Replacing the Air Filter
49
Replacing the Fan Unit
49
Figure 11 - Replacing the Fan Unit
49
Calibrating the Volt / Amp Multimeter
50
Procedure 10 - Replacing the Fan Unit
50
Resetting the Rectifier after an HVSD ( High Voltage Shutdown )
51
Procedure 11 - Calibrating the Meter
51
Procedure 12 - Resetting the Rectifier after a High Voltage Shutdown
51
7 Troubleshooting
53
Table 16 - Diagnosing System Faults
53
8 Appendix A : Replacement Parts
55
9 Appendix B : Technical Service Assistance
57
Local Toll-Free Prefixes
57
Toll-Free Technical Assistance Numbers
58
10 Abbreviations and Acronyms
59
Related Products
Emerson Rosemount 2160
Emerson Avocent AutoView 2108
Emerson Rosemount 2140
Emerson Rosemount 2110
Emerson 2100
Emerson 2100E
Emerson Rosemount 2511
Emerson Rosemount 2501
Emerson Rosemount 2521 Series
Emerson Rosemount 2521S
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals