Monitor display and monitor output signals
Pr. 37
0
(initial
value)
0.01–9998
Tab. 6-18: Setting range of parameter 37
Machine speed conversion formula: Pr. 37 × frequency/60Hz
Hz is displayed in 0.01Hz increments and machine speed is in 0.001.
NOTES
Under V/f control, the output frequency of the inverter is displayed in terms of synchronous
speed, and therefore, displayed value = actual speed + motor slip. The display changes to
the actual speed (estimated value calculated based on the motor slip) when slip compensa-
tion was made valid.
Refer to Pr. 52 when you want to change the PU main monitor (PU main display).
Since the panel display of the operation panel is 4 digits in length, the monitor value of more
than "9999" is displayed "----".
When the machine speed is displayed on the FR-PU04/FR-PU07, do not change the speed
by using an up/down key in the state where the set speed exceeding 65535 is displayed. The
set speed may become arbitrary value.
While the machine speed is displayed on the monitor, values of other parameters related to
speed (Pr. 1, etc.) are in frequency increments. Set other parameters (Pr. 1, etc) related to
speed in increments of frequency.
Due to the limitations on the resolution of the set frequency, the indication in the second dec-
imal place may differ from the setting.
b
CAUTION:
Make sure that the running speed setting is correct. Otherwise, the motor might run
at extremely high speed, damaging the machine.