Mitsubishi D700-SC Frequency Inverter
Easy Start Guide
The Mitsubishi D700-SC Frequency Inverter range is
available to order from inverterdrive.com
This guide is intended to complement the user manual provided by the manufacturer.
It is provided as a basic introduction to the product for Inverter Drive Supermarket customers.
It should not be used as a replacement for the manual issued by the manufacturer.
This product is not a safety device. All safety considerations including but not
limited to Emergency Stop provision should be assessed separately and are
outside the scope of this guide.
Issue 1
20180129
Table of Contents
loading

Summary of Contents for Mitsubishi Electric D700-SC

  • Page 1 Mitsubishi D700-SC Frequency Inverter Easy Start Guide The Mitsubishi D700-SC Frequency Inverter range is available to order from inverterdrive.com This guide is intended to complement the user manual provided by the manufacturer. It is provided as a basic introduction to the product for Inverter Drive Supermarket customers.
  • Page 2: Table Of Contents

    Easy Start Guide Mitsubishi D700-SC Series Inverter Contents Page 1 Contents Page 2 Power and Motor Connections (Single Phase) Page 3 Power and Motor Connections (Three Phase) Page 4 Motor Connections - Star and Delta Page 5 Parameters - Overview...
  • Page 3: Power And Motor Connections (Single Phase)

    Easy Start Guide Mitsubishi D700-SC Series Inverter 1. Power and Motor Connections (Single Phase) Before commencing, confirm that the Inverter and all cables are completely isolated from the power supply, have been isolated for at least 5 minutes and that the motor is not turning.
  • Page 4: Power And Motor Connections (Three Phase)

    Easy Start Guide Mitsubishi D700-SC Series Inverter 2. Power and Motor Connections (Three Phase) Before commencing, confirm that the Inverter and all cables are completely isolated from the power supply, have been isolated for at least 5 minutes and that the motor is not turning.
  • Page 5: Motor Connections - Star And Delta

    Easy Start Guide Mitsubishi D700-SC Series Inverter 3. Motor Connections - Star and Delta Dual voltage induction motors typically include The selection of Star or Delta is not optional terminal boxes with six points. The points can and must match the supply voltage.
  • Page 6: Parameters - Overview

    Easy Start Guide Mitsubishi D700-SC Series Inverter 4. Parameters - overview The Inverter contains a number of settings The parameters contain critical information which can be changed to tailor it for use in a essential to the correct operation of the wide range of applications.
  • Page 7: How To Set A Parameter Value

    Easy Start Guide Mitsubishi D700-SC Series Inverter 6. How to set a Parameter value 6.1 Select “PU” operation mode. With the motor stopped, press the “PU/EXT” key repeatedly until the “PU” indicator is illuminated and “0.00" is displayed. Note: If the operation mode is not changed to PU the Inverter will not allow parameter values to be changed and return an Er.
  • Page 8: How To Operate The Inverter From The Keypad

    Easy Start Guide Mitsubishi D700-SC Series Inverter 7. How to operate the Inverter from the keypad 7.1 Select “MON” and “PU” modes. With the motor stopped, press the “PU/EXT” key repeatedly to cycle through operation modes until the “PU” indicator is illuminated and “0.00" is displayed.
  • Page 9: How To Enable Sensorless Vector Mode

    Easy Start Guide Mitsubishi D700-SC Series Inverter 8. How to enable Sensorless Vector mode The standard motor control mode of the D700 These calculations require an “auto tuning” run SC Inverter is VxF. This simple mode controls during which the Inverter operates for approx.
  • Page 10: How To Connect And Configure A Potentiometer For Remote Speed Control

    Easy Start Guide Mitsubishi D700-SC Series Inverter 9. How to connect and configure a Potentiometer for remote speed control If speed control via the integrated dial is A Potentiometer of 1kOhm rating should be unsuitable for the application, a remote used.
  • Page 11: How To Connect And Configure A Run Forward Or

    Easy Start Guide Mitsubishi D700-SC Series Inverter 10. How to connect and configure a Run Forward or Run Reverse switch The procedure described in section 7 enables This section explains how to enable 2-wire Run/Stop operation via the red and green control with Run Forward / Stop / Run Reverse buttons on the Inverter keypad.
  • Page 12: How To Connect And Configure A Run/Stop Switch

    Easy Start Guide Mitsubishi D700-SC Series Inverter 11. How to connect and configure a Run/Stop switch with Forward/Reverse selection The procedure described in section 7 enables This section explains how to enable 2-wire Run/Stop operation via the red and green control with Run/Stop and Forward/Reverse buttons on the Inverter keypad.
  • Page 13: How To Configure "3-Wire" Control With Run/Stop

    Easy Start Guide Mitsubishi D700-SC Series Inverter 12. How to configure “3-Wire” control with Run/Stop pushbuttons and Forward/Reverse selection The procedure described in section 7 enables This section explains how to enable 3-wire Run/Stop operation via the red and green control with Run and Stop via pushbuttons and buttons on the Inverter keypad.
  • Page 14: Brake Resistor Connection

    Easy Start Guide Mitsubishi D700-SC Series Inverter 13. Brake Resistor Connection (if available) Before commencing, confirm that the Inverter and all cables are completely isolated from the power supply, have been isolated for at least 5 minutes and that the motor is not turning.
  • Page 15: How To Reset The Inverter To Factory Defaults

    Easy Start Guide Mitsubishi D700-SC Series Inverter 14. How to reset the Inverter to Factory Defaults 14.1 Select “PU” operation mode. With the motor stopped, press the “PU/EXT” key repeatedly to cycle through operation modes until the “PU” indicator is illuminated and “0.00" is displayed.

Table of Contents