Parameter
Parameter
Func-
Name
tion
555
Current average time
556
Data output mask time
Current average value
557
monitor signal output
reference current
561
Refer to Pr. 9
563
Refer to Pr. 52
564
—
571
Refer to Pr. 13
575
–
Refer to Pr. 127
577
Traverse function
592
selection
Maximum amplitude
593
amount
Amplitude
594
compensation amount
during deceleration
Amplitude
595
compensation amount
during acceleration
Amplitude acceleration
596
time
Amplitude deceleration
597
time
—
611
Refer to Pr. 57
Speed smoothing
653
control
665
Refer to Pr. 882
—
872
Refer to Pr. 251
Tab. 6-1:
Parameter overview (23)
FR-D700 SC EC
Incre-
Initial
Setting
ments
value
range
0.1s
1s
0.1–1.0s
0.1s
0s
0–20s
Rated
0.01A
inverter
0–500A
current
0
1
1
0
2
0.1%
10%
0–25%
0.1%
10%
0–50%
0.1%
10%
0–50%
0.1s
5s
0.1–3600s
0.1s
5s
0.1–3600s
0.1%
0
0–200%
Description
Set the time taken to average the
current during start bit output
(1s).
Set the time for not obtaining
(mask) transient state data.
Set the reference (100%) for out-
putting the signal of the current
average value
Traverse function invalid
Traverse function is valid only in
the External operation mode
Traverse function is valid
independently of operation mode
Amplitude amount during traverse
operation
Compensation amount at the time
of amplitude inversion
(acceleration to deceleration)
Compensation amount at the time
of amplitude inversion
(deceleration to acceleration)
Acceleration time during traverse
operation
Deceleration time during traverse
operation
The torque fluctuation is reduced
to reduce vibration due to
mechanical resonance.
Parameter overview
All
Para-
Para-
Para-
meter
meter
meter
copy
clear
clear
Refer
to
page
✔: enabled
—: disabled
✔
✔
✔
✔
✔
✔
6-277
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
6-264
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
6-146
6 - 23