Figure 13-45 Sm-I/O 120V Relay Diagram - Emerson Unidrive SPM User Manual

Variable speed ac drive
Table of Contents
Safety
Product
Introduction
Information
Information
configuration

Figure 13-45 SM-I/O 120V relay diagram

SM-I/O 120V parameters
Parameter
x.01
Solutions Module ID
x.02
Solutions Module software version
x.03
T4 digital input 3 state
x.04
T5 digital input 4 state
x.05
T7 digital input 5 state
x.06
T8 digital input 6 state
x.07
Relay 1 state
x.08
Relay 2 state
x.09
T1 digital input 1 state
x.10
T2 digital input 2 state
x.11
T1 digital input 1 invert
x.12
T2 digital input 2 invert
x.13
T4 digital input 3 invert
x.14
T5 digital input 4 invert
x.15
T7 digital input 5 invert
x.16
T8 digital input 6 invert
x.17
Relay 1 invert
x.18
Relay 2 invert
x.20
Digital I/O read word
x.21
T1 digital input 1 destination
x.22
T2 digital input 2 destination
x.23
T4 digital input 3 destination
x.24
T5 digital input 4 destination
x.25
T7 digital input 5 destination
x.26
T8 digital input 6 destination
x.27
Relay 1 source
x.28
Relay 2 source
x.50
Solutions Module error status*
x.51
Solutions Module software sub-version
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
*See trip SLX.Er, Automation (I/O Expansion) module category on page 286.
242
System
Mechanical
Electrical
Getting
Installation
Installation
Started
Relay 1
state
Relay 1
x.07
10
11
0V
Relay 2
state
Relay 2
x.08
12
11
0V
Range( )
0 to 599
0.00 to 99.99
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
0 to 255
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
0 to 255
Uni
Unipolar
NC
Not copied
RA
www.controltechniques.com
Basic
Running
Optimization
parameters
the motor
Relay 1
source
Relay 1
invert
x.17
x(-1)
Relay 2
source
Relay 2
invert
x.18
x(-1)
Key
Input
X
X
0.XX
terminals
X
Output
0.XX
X
terminals
The parameters are all shown at their default settings
0 to 99
Bi
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
SMARTCARD
Onboard
Advanced
Technical
operation
PLC
parameters
x.27
Any
parameter
??.??
??.??
x.28
Any
parameter
??.??
??.??
Read-write (RW)
parameter
Read-only (RO)
parameter
Default( )
206
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Txt
Text string
US
User save
Unidrive SPM User Guide
UL Listing
Diagnostics
Data
Information
Type
RO Uni
PT US
RO Uni
NC PT
RO Bit
NC PT
RO Bit
NC PT
RO Bit
NC PT
RO Bit
NC PT
RO Bit
NC PT
RO Bit
NC PT
RO Bit
NC PT
RO Bit
NC PT
RW Bit
US
RW Bit
US
RW Bit
US
RW Bit
US
RW Bit
US
RW Bit
US
RW Bit
US
RW Bit
US
RO Uni
NC PT
RW Uni DE
PT US
RW Uni DE
PT US
RW Uni DE
PT US
RW Uni DE
PT US
RW Uni DE
PT US
RW Uni DE
PT US
RW Uni
PT US
RW Uni
PT US
RO Uni
NC PT
RO Uni
NC PT
PS
Power down save
Issue Number: 3

Hide quick links:

Table of Contents
loading

Table of Contents