Toshiba e-STUDIO 2555C Service Manual page 123

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 2555C:
Abnormality detection by the thermistors
The following table shows the conditions for judging the temperature abnormality of the fuser belt, and
the detecting timing.
Check timing
Error code
Power ON
C449
When pre-
C449
running end
C445
temperature
C446
or ready
temperature
is detected
During ready
C449
C447
C447
During
C449
printing
C447
C447
C447
C447
At energy
C449
saving mode
At paper jam
C449
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
Counter
Center
9 Fixed
220°C or above
22 Fixed
220°C or above
5 Not fixed Ready temperature
or above
6 Fixed
23 Fixed
220°C or above
7 Fixed
0°C or below
63 Fixed
-
25 Fixed
220°C or above
24 Fixed
0°C or below
64 Fixed
-
65 Fixed
40°C or below
66 Fixed
-
27 Fixed
220°C or above
29 Fixed
220°C or above
3 - 83
Edge
235°C or above
235°C or above
On usual
-
235°C or above
On usual
-
0°C or below
235°C or above
On usual
-
0°C or below
-
40°C or below
235°C or above
On usual
235°C or above
On usual
e-STUDIO2555C/3055C/3555C/4555C/5055C
OUTLINE OF THE MACHINE
Error
judging
timing
3

Hide quick links:

loading