D-Link DXS-3600 Series Reference Manual page 916

Dxs-3600 series layer 2/3 managed 10gigabit ethernet switch
Hide thumbs Also See for DXS-3600 Series:
Table of Contents
DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
Parameters
SECONDS
Default
By default, this value is 5 seconds.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
The register-probe time is the time before the Register-Stop Timer (RST) expires when a DR may send a
Null-Register to the RP to cause it to resend a Register-Stop message.
Example
This example shows how to configure the register-probe time to 10 seconds.
Switch# configure terminal
Switch(config)# ipv6 pim register-probe 10
Switch(config)#
78-11
ipv6 pim register-suppresion
This command is used to configure the register-suppression time. Use the no form of the command to
revert to the default setting.
ipv6 pim register-suppression SECONDS
no ipv6 pim register-suppression
Parameters
SECONDS
Default
By default, this value is 60 seconds.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
This command only affects PIM-SM operation.
When a DR receives the register-stop message, it will start the suppression timer. During the suppression
time a DR will stop sending Register-encapsulated data to the RP. This timer should be configured on the
designated router. The value of the Register Probe Time must be less than half the value of the Register
Specifies the register probe time value in seconds. The range is from 1
to 127.
Specifies the register suppression timeout value in seconds. The range
is from 3 to 65535.