Care and Cleaning
Replacing the air cleaning lter
Remove the air lter. (Refer to step 1 in "Replacing the air lter".)
1
Release 2 latches a of the lter holder, and turn over the holder
2
in direction of arrow b.
Remove the soiled air cleaning lter c.
Note:
Air cleaning lter is attached on each air lter.
a
c
Attach new or maintained air cleaning lter d to the lter holder.
3
New air cleaning lter can be attached to either of the right holder
or the left holder.
d
Latch 2 corners of the lter holder e to the air lter rmly.
4
e
Reinstall the air lter. (Refer to step 6 in "Cleaning the air lter".)
5
Close the intake grille rmly.
6
(Refer to step 4 in "Cleaning the intake grille" on page 10.)
a
b
e
AIR CONDITIONER Wall Mounted Type
Following 2 types of air cleaning lters are used in this product.
When you replace them, purchase dedicated air cleaning lters for this
product.
Apple-catechin lter: UTR-FA16
The Apple-catechin lter uses static electricity to clean ne particles
and dust in the air such as tobacco smoke and plant pollen that are
too small to see.
• This lter is disposable. Do not wash or reuse it.
• Once you open the package, use it as soon as possible. The
cleaning effect is reduced if the lter is left with the package opened.
• Replace the lter once every 3 months under normal use.
• By setting the fan speed high, the air cleaning effect increases.
Ion deodorization lter: UTR-FA16-2
The lter deodorizes by powerfully decomposing absorbed odors
using the oxidizing and reducing effects of ions generated by the
ultra- ne-particle ceramic.
• To maintain the deodorizing effect, clean the lter once every 3
months as follows:
1. Remove the lter.
2. Flush the lter with high-pressure hot water until the surface of
the lter is covered with water.
3. Wash the lter gently with diluent nuetral detergent. Do not wash
it by wringing or rubbing to prevent reducing the deodorizing
effect by damage.
4. Rinse the lter well with water ow.
5. Dry the lter throughly in a shaded place.
6. Reinstall the lter to the indoor unit.
• Replace the lter once every 3 years under normal use.
After extended non-use of the unit
If you have shut down the indoor unit for 1 month or more, perform the
FAN operation for half a day to dry the internal parts throughly before
you perform normal operation.
Additional inspection
After long period of use, accumulated dust inside the indoor unit may
reduce the product performance even if you have maintained the unit
with instructed daily care or cleaning procedures written in this manual.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.