Fujitsu ASTG12CMCB Installation Manual

Wall mounted type
Hide thumbs Also See for ASTG12CMCB:

AIR CONDITIONER

Wall Mounted Type

R32
R32.
For authorized service personnel only.

1. SAFETY PRECAUTIONS

• Be sure to read this Manual thoroughly before installation.
• The warnings and precautions indicated in this Manual contain important information
pertaining to your safety. Be sure to observe them.
• Hand this Manual, together with the Operating Manual, to the customer. Request the
customer to keep them on hand for future use, such as for relocating or repairing the
unit.
Indicates a potentially or imminently hazardous situation
WARNING
which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation that may result in
CAUTION
minor or moderate injury or damage to property.
WARNING
• Installation of this product must be done by experienced service technicians or profes-
sional installers only in accordance with this manual. Installation by non-professional
or improper installation of the product might cause serious accidents such as injury,
water leakage, electric shock, or fi re. If the product is installed in disregard of the
instructions in this manual, it will void the manufacturer's warranty.
• Do not turn on the power until all work has been completed. Turning on the power
before the work is completed can cause serious accidents such as an electric shock
or a fi re.
• If refrigerant leaks when you are working, ventilate the area. If the leaking refrigerant
is exposed to a direct fl ame, it may produce a toxic gas.
• Installation must be performed in accordance with regulations, codes, or standards for
electrical wiring and equipment in each country, region, or the installaton place.
• Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
• The appliance shall be stored in a room without continuously operating ignition
sources (for example: open fl ames, an operating gas appliance or an operating
electric heater.
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odour.
CAUTION
• Read carefully all of safety information written in this manual before you install or use
the air conditioner.
• Install the unit by following local codes and regulations in force at the place of installa-
tion, and the instructions provided by the manufacturer.
• This unit is part of a set constituting an air conditioner. The unit must not be installed
alone or be installed with non-authorized device by the manufacturer.
• Always use a separate power supply line protected by a circuit breaker operating on all
wires with a distance between contact of 3 mm for this unit.
• To protect the persons, earth (ground) the unit correctly, and use the power cable
combined with an Earth Leakage Circuit Breaker (ELCB).
• The units are not explosion proof, and therefore should not be installed in explosive
atmosphere.
• To avoid getting an electric shock, never touch the electrical components soon after
the power supply has been turned off. After turning off the power, always wait 5 min-
utes or more before you touch the electrical components.
• This unit contains no user-serviceable parts. Always consult experienced service
technicians for repairing.

INSTALLATION MANUAL

PART No. 9333005201
Contents
1.
SAFETY PRECAUTIONS .................................................................. 1
2.
ABOUT THIS PRODUCT................................................................... 3
3.
GENERAL SPECIFICATION ............................................................. 4
4.
ELECTRICAL REQUIREMENT ......................................................... 4
5.
SELECTING THE MOUNTING POSITION ....................................... 4
6.
INSTALLATION WORK ..................................................................... 5
7.
ELECTRICAL WIRING ..................................................................... 7
8.
FINISHING ........................................................................................ 8
9.
FRONT PANEL REMOVAL AND INSTALLATION ............................. 8
10. TEST RUN ......................................................................................... 8
11. REMOTE CONTROLLER INSTALLATION ........................................ 9
12. OPTIONAL KIT INSTALLATION ........................................................ 9
13. INSTALLATION WORK (OPTION) .................................................... 9
15. FUNCTION SETTING...................................................................... 12
16. CUSTOMER GUIDANCE ................................................................ 14
17. ERROR CODES .............................................................................. 14
CAUTION
• When moving or relocating the air conditioner, consult experienced service technicians
for disconnection and reinstallation of the unit.
• Do not place any other electrical products or household belongings under indoor unit
or outdoor unit. Condensation dripping from the unit might get them wet, and may
cause damage or malfunction of your property.
• Be careful not to scratch the air conditioner when handling it.
• After installation, explain correct operation to the customer, using the operating manual.
Precautions for using R32 refrigerant
The basic installation work procedures are the same as conventional refrigerant (R410A,
R22) models.
However, pay careful attention to the following points:
Since the working pressure is 1.6 times higher than that of refrigerant R22 models,
some of the piping and installation and service tools are special. (See "2.1. Special
tools for R32 (R410A)".)
Especially, when replacing a refrigerant R22 model with a new refrigerant R32 model,
always replace the conventional piping and fl are nuts with the R32 and R410A piping and
fl are nuts on the outdoor unit side.
For R32 and R410A, the same fl are nut on the outdoor unit side and pipe can be used.
Models that use refrigerant R32 and R410A have a different charging port thread diam-
eter to prevent erroneous charging with refrigerant R22 and for safety. Therefore, check
beforehand. [The charging port thread diameter for R32 and R410A is 1/2-20 UNF.]
Be more careful than R22 so that foreign matter (oil, water, etc.) does not enter the
piping. Also, when storing the piping ,securely seal the opening by pinching, taping, etc.
(Handling of R32 is similar to R410A.)
CAUTION
1-Installation (Space)
• That the installation of pipe-work shall be kept to a minimum.
• That pipe-work shall be protected from physical damage.
• That compliance with national gas regulations shall be observed.
• That mechanical connections shall be accessible for maintenance purposes.
• In cases that require mechanical ventilation, ventilation openings shall be kept clear
of obstruction.
• When disposing of the product is used, be based on national regulations, properly
processed.
2-Servicing
2-1 Service personnel
• Any person who is involved with working on or breaking into a refrigerant circuit
should hold a current valid certifi cate from an industry-accredited assessment
authority, which authorises their competence to handle refrigerants safely in accor-
dance with an industry recognised assessment specifi cation.
• Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be
carried out under the supervision of the person competent in the use of fl ammable
refrigerants.
• Servicing shall be performed only as recommended by the manufacturer.
En-1
Table of Contents
loading

Summary of Contents for Fujitsu ASTG12CMCB

  • Page 1: Table Of Contents

    INSTALLATION MANUAL AIR CONDITIONER Wall Mounted Type PART No. 9333005201 Contents SAFETY PRECAUTIONS ..............1 ABOUT THIS PRODUCT..............3 GENERAL SPECIFICATION ............. 4 ELECTRICAL REQUIREMENT ............4 SELECTING THE MOUNTING POSITION ........4 INSTALLATION WORK ..............5 ELECTRICAL WIRING ..............7 FINISHING ..................
  • Page 2 CAUTION CAUTION 2-2 Work 3-Repairs to sealed components • During repairs to sealed components, all electrical supplies shall be disconnected • Prior to beginning work on systems containing fl ammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrig- from the equipment being worked upon prior to any removal of sealed covers, etc.
  • Page 3: About This Product

    Explanation of symbols displayed on the indoor unit or outdoor unit. CAUTION This symbol shows that this appliance uses a fl ammable 9-Charging procedures refrigerant. WARNING • In addition to conventional charging procedures, the following requirements shall be If the refrigerant is leaked and exposed to an external igni- followed.
  • Page 4: General Specification

    2.2. Accessories CAUTION The following installation accessories are supplied. Use them as required. • Wrap heat insulation around both of the gas pipe and the liquid pipe. No heat-insulation work or incorrect heat-insulation work may cause water leaks. Name and Shape Q’ty Name and Shape Q’ty...
  • Page 5: Installation Work

    6. INSTALLATION WORK WARNING Always use the wall pipe. If the wall pipe is not used, the cable that is connected between the indoor unit and the outdoor unit may touch metal, and cause an electric WARNING discharge. During transportation and relocation shall be covered by wall hook bracket to the con- necting pipe.
  • Page 6 Check if [L] is flared uniformly For left outlet piping (Drain and is not cracked or scratched. hose), cut off the piping outlet cutting groove with a hacksaw. Pipe Drain cap Remove the drain cap by pull- Indoor unit ing at the projection at the end Dimension A [mm] drain hose Pipe outside diameter...
  • Page 7: Electrical Wiring

    7.3. How to connect wiring to the terminals 7. ELECTRICAL WIRING Caution when wiring cable CAUTION To strip off the insulation of a lead wire, always use a special tool such as a wire strip- per. If there is no special tool, carefully strip off the insulation by using a knife or other utensil.
  • Page 8: Finishing

    9.1. Front panel removal 8. FINISHING (1) Remove intake grille (Reference the intake grille removal.) (1) Insulate between pipes. (2) Remove 3 caps. • Insulate suction and discharge pipes separately. (3) Remove wire cover. • For rear, right, and bottom piping, overlap the connection pipe heat insulation and (4) Remove 7 screws.
  • Page 9: Remote Controller Installation

    [Using the wired remote controller] (Option) 13. INSTALLATION WORK (OPTION) For the operation method, refer to the operating manual. (1) Stop the air conditioner operation. (2) Press the MODE button and the FAN button simultaneously for 2 seconds or more to CAUTION start the test run.
  • Page 10 (5) Install the control box cover as shown below. (4) Remove the wires from the three fixtures. (See the figure below) (Align the cover with the upper and lower right corners as indicated by the triangular • Leave the thick green wire in fixture C and remove the rest of the wires. symbols on the figure.
  • Page 11 (2) Use the hole on the motor cover and secure the wire from the communication box with the provided cable tie. (See the figure below) Cut away the tip of the cable tie. Hole Cable tie Wired remote controller cable Communication kit connector External connect kit cable (sold separately) (5) Fasten the earth wire (green) in the communication box together with the earth...
  • Page 12: Selecting The Remote Controller Custom Code

    (8) Paste protect seals (2 locations) to prevent the wires from sticking out. Entering the Function Setting Mode While pressing the POWERFUL button and TEMP. ( ) button simultaneously, press the RESET button to enter the function setting mode. Selecting the Function Number and Setting Value [Reverse cycle model] (1) Press the TEMP.
  • Page 13 Room temperature sensor switching Temperature correction 15.2. (Only for Wired remote controller) When using the Wired remote controller temperature sensor, change the setting to “Both” NOTE: (01). (♦... Factory setting) When changing Function 95, perform this setting before other Room temp. control settings (Function 30, 31, 35, 36).
  • Page 14: Customer Guidance

    Room temperature control for wired remote controller sensor Error display Wired Depending on the installed environment, correction of the wire remote temperature sensor remote TIMER ECONOMY may be required. Description OPERATION controller lamp lamp Select the appropriate control setting according to the installed environment. lamp (green) Error code (orange)