Before using this product, read these instructions thoroughly and keep this manual for future reference.

Safety Precautions

To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply to the
following safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classifi ed as follows:
This mark warns of death or serious injury.
This mark denotes an action that is PROHIBITED.
• Explanation of symbols displayed on the indoor unit or outdoor unit.
This symbol shows that this appliance uses a fl ammable refrigerant. If the refrigerant is leaked and exposure to an external
WARNING
ignition source, there is a risk of fi re.
CAUTION
This symbol shows that the Operation Manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this equipment with reference to the Installation Manual.
CAUTION
This symbol shows that information is available such as the Operating Manual or Installation Manual.
• The appliance contains no user-serviceable parts. Always
consult authorized service personnel for repairing, installation,
and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or fi re.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should only be replaced by authorized
service personnel.
• In the event of refrigerant leakage, be sure to keep away
from fi re or any fl ammables, and consult authorized service
personnel.
• If you see lightning or hear thunder, there might be a lightning
strike.
To prevent electric shock hazard, turn off the air conditioner
by using the remote controller, and do not touch the unit or
the power plug during thunderstorm.
PART No. 9333003283-02
R32
REFRIGERANT
This Air Conditioner contains and
operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
WARNING
OPERATING MANUAL
Contents
Safety Precautions ............................................................... 1
Indoor Unit Overview and Operations .................................. 3
Timer Operation.................................................................... 6
Human Sensor (Energy Saving) ........................................... 8
General Informations on Operation ...................................... 9
Care and Cleaning.............................................................. 10
Troubleshooting .................................................................. 12
This mark warns of injury or damage to property.
This mark denotes an action that is COMPULSORY.
WARNING
• The appliance shall be stored in a room without continuously
operating ignition sources (for example: open fl ames, an
operating gas appliance or an operating electric heater).
• The appliance shall be stored in a well-ventilated area.
• Be aware that refrigerants may not contain an odour.
• The appliance shall be stored so as to prevent mechanical
damage from occurring.
• Disposing of the product shall be done properly, in
compliance with national or regional regulations.
• During transportation or relocation of the indoor unit, pipes
shall be covered with the wall hook bracket for protection.
Do not move the appliance by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
fl ammable gas to leak during operation).
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of
the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play
with the appliance.
CAUTION
(continued)
En-1
Table of Contents
loading

Summary of Contents for Fujitsu ASTG09KMCB

  • Page 1: Table Of Contents

    Demand Response and Indoor Unit Operation ....8 General Informations on Operation ........9 Care and Cleaning.............. 10 Troubleshooting ..............12 ASTG09KMCB ASTG12KMCB Before using this product, read these instructions thoroughly and keep this manual for future reference. Safety Precautions To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply to the following safety precautions.
  • Page 2 Safety Precautions (continued) WARNING • Do not install the unit in area fi lled with mineral oil such as a • Do not insert your fi ngers or any other objects into outlet factory or area containing a large amount of splashed oil or port, open panel, or intake grille.
  • Page 3: Indoor Unit Overview And Operations

    AIR CONDITIONER Wall Mounted Type Indoor Unit Overview and Operations Intake grille 11 TIMER indicator (orange) Before starting operation, make sure that the intake grille has been Lights in TIMER operation, and blinks slowly when the timer setting shut completely. Incomplete closing may have an effect on the proper error is detected.
  • Page 4: Remote Controller Overview And Operations

    Remote Controller Overview and Operations CAUTION • To prevent malfunction or damage of the remote controller: • If leaking battery fl uid comes in contact with your skin, eyes, or mouth, immediately rinse with plenty of clean water, and - Place remote controller at where will not be exposed to consult your physician.
  • Page 5 AIR CONDITIONER Wall Mounted Type Remote Controller Overview and Operations (continued) Signal transmitter 19 SEND button Aim at the signal receiver of the indoor unit properly. Used for sending the timer/clock setting. • Signal transmit indicator on the remote controller display shows 20 TIMER SETTING button See page 6 that the signal from the remote controller is being transmitted.
  • Page 6: Timer Operation

    Timer Operation  Remote controller custom code setting Note for timer settings: Any interruption of the power supply, such as a blackout or cutting off When two or more air conditioners are installed in a room and the of a circuit breaker, makes the set internal clock incorrect. remote controller is operating an air conditioner other than the one you In such a case, the TIMER indicator on the indoor unit blinks, and you wish to set, change the custom code of the remote controller to operate...
  • Page 7 AIR CONDITIONER Wall Mounted Type Timer Operation (continued) To set the WEEKLY timer, fi rst follow steps 1~3 on page 6 for the ON/ WEEKLY timer OFF timer. ON and OFF timer can be combined, and up to 4 reservations (program Select the program number and the day using the SELECT ) per day and 28 reservations per week.
  • Page 8: Human Sensor (Energy Saving)

    If the air conditioner is under demand controlling, consult the issues with your electricity supplier. If they are not demand controlling the air conditioner, refer to your warranty card for the contact details of Fujitsu General (AUST.) PTY LIMITED or visit our website : www.fujitsugeneral.com.au OPERATING MANUAL...
  • Page 9: General Informations On Operation

    AIR CONDITIONER Wall Mounted Type General Informations on Operation Automatic defrosting operation Heating performance When outdoor temperature is very low with high humidity, frost • This air conditioner operates on the heat-pump principle, may form on the outdoor unit during the heating operation, and absorbing heat from air outdoors and transferring that heat it could reduce the operating performance of the product.
  • Page 10: Care And Cleaning

    Care and Cleaning CAUTION • Before cleaning the indoor unit, be sure to turn it off and all the power supply has been disconnected. • Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an effect on the proper working or performance of the air conditioner.
  • Page 11 AIR CONDITIONER Wall Mounted Type Care and Cleaning Following 2 types of air cleaning fi lters are used in this product. Replacing the air cleaning fi lter When you replace them, purchase dedicated air cleaning fi lters for this Remove the air fi lter. (Refer to step 1 in “Replacing the air fi lter”.) product.
  • Page 12: Troubleshooting

    Troubleshooting WARNING In following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel. As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off. •...