Fujitsu ASTG09LVCA Operating Manual

Fujitsu ASTG09LVCA Operating Manual

Wall mounted type
ROOM AIR CONDITIONER

WALL MOUNTED TYPE

KEEP THIS MANUAL FOR FUTURE REFERENCE
OPERATING MANUAL
R410A
REFRIGERANT
This Air Conditioner contains and operates
with refrigerant R410A and Polyol Ester oil.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance and/or service of this product.
P/N9318657005
Table of Contents
loading

Summary of Contents for Fujitsu ASTG09LVCA

  • Page 1: Wall Mounted Type

    ROOM AIR CONDITIONER OPERATING MANUAL WALL MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A and Polyol Ester oil. THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL. Refer to Commonwealth, State, Territory and local legislation, regulations, codes, installation &...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ........En-1 10°C HEAT OPERATION ........En-11 FEATURES AND FUNCTIONS ......En-2 ECONOMY OPERATION ........En-11 NAME OF PARTS ..........En-4 SWING OPERATION ......... En-12 PREPARATION ............ En-5 MANUAL AUTO OPERATION ......En-12 OPERATION ............En-6 CLEANING AND CARE ........En-13 TIMER OPERATION ..........
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS G Ensure that any electronic equipment is at least one meter away from either the in- CAUTION! door or outdoor units. G Avoid installing the air conditioner near a fireplace or other heating apparatus. G When installing the indoor and outdoor unit, take precautions to prevent access to infants.
  • Page 4 Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 To facilitate explanation, the accompanying illus- tration has been drawn to show all possible indica- tors; in actual operation, however, the display will only show those indicators appropriate to the current operation.
  • Page 5: Name Of Parts

    NAME OF PARTS Fig. 1 Indoor Unit Fig. 5 Remote Controller 1 Operating Control Panel (Fig. 2) G Signal Transmitter 2 MANUAL AUTO button H MODE button ● I 10°C HEAT button When kept on pressing the MANUAL AUTO button for more than 10 seconds, J SET TEMP.
  • Page 6: Preparation

    PREPARATION CAUTION! Turn on the Power G Take care to prevent infants from accidentally swallowing batteries. Turn on the circuit breaker. G When not using the Remote Controller for an extended period, remove the batteries to avoid possible leakage and damage to the unit.
  • Page 7: Operation

    OPERATION To Select Mode Operation Press the START/STOP button (Fig.5 O). The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 5) will light. The air conditioner will start operating. Press the MODE button (Fig.5 H) to select the desired mode. Each time the button is pressed, the mode will change in the following order.
  • Page 8 OPERATION To Stop Operation Press the START/STOP button (Fig. 5 O). The OPERATION Indicator Lamp (green) (Fig. 3 5) will go out. About AUTO CHANGEOVER Operation G When AUTO CHANGEOVER operation first selected, the fan will oper- AUTO: ate at very low speed for about two minute, during which time the indoor unit detects the room conditions and selects the proper opera- tion mode.
  • Page 9: Timer Operation

    TIMER OPERATION Before using the timer function, be sure that the Remote Controller is set to the correct current time ( P. 5). To Use the ON timer or OFF timer Press the START/STOP button (Fig. 5 O) To Cancel the Timer Use the TIMER button to select “CANCEL”.
  • Page 10: Sleep Timer Operation

    SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operation is stopped. To Use the SLEEP Timer To Cancel the Timer: While the air conditioner is operating or stopped, press the Use the TIMER MODE button to select SLEEP button (Fig.
  • Page 11: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION Vertical (up-down) direction of airflow is adjusted by pressing the Remote Controller’s SET button. Horizontal (right-left) Airflow direction is adjusted manually, by moving the Airflow Direction Louvers. Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical Airflow direction louvers are stopped.
  • Page 12 10°C HEAT OPERATION • The room temperature can be maintained at 10°C by pressing the 10°C HEAT button (Fig.5 G) so as to prevent the room temperature from falling too far. To use 10°C HEAT OPERATION While 10˚C HEAT OPERATION is in progress, only Airflow direction set can be used.
  • Page 13: Swing Operation

    SWING OPERATION Begin air conditioner operation before performing this procedure. To select SWING Operation Press the SWING button (Fig. 5 Q). The SWING Display (Fig. 6 Y) will light. In this mode, the Airflow Direction Louvers will swing automatically to direct the air flow both up and down.
  • Page 14: Cleaning And Care

    CLEANING AND CARE G Before cleaning the unit, be sure to stop the unit. CAUTION! G Turn off the electrical breaker. G When removing or replacing the air filters, be sure not to touch the heat exchanger, as personal injury may result. Cleaning the Air Filter 1.
  • Page 15 CLEANING AND CARE Air Cleaning Filter Installation 2. Remove the air cleaning filters attached to the frames of the front panel. 1. Open the Intake Grille and remove the Air filters. Air cleaning filter frame 2. Attach the air cleaning filter to the frame of the front panel.
  • Page 16: Troubleshooting

    TROUBLESHOOTING In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec- WARNING! trical breaker and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
  • Page 17: Operating Tips

    TROUBLESHOOTING Symptom Items to check See Page G Has the circuit breaker been turn off? CHECK ONCE Doesn’t operate at all: MORE G Has there been a power failure? — G Has a fuse blown out, or a circuit breaker been tripped? G Is the timer operating? 8 - 9 G Is the Air Filter dirty?
  • Page 18: Auto Restart

    OPERATING TIPS AUTO Restart In Event of Power Interruption G The power supply to the air conditioner is stopped by a G If a power interruption occurs during TIMER operation, the power interruption. The air conditioner will then restart timer will be reset and the indoor unit will begin (or stop) automatically in its previous mode when the power is operation at the new time setting.

This manual is also suitable for:

Astg12lvcaAstg18lvca

Table of Contents