Before using this product, read these instructions thoroughly and keep this manual for future reference.
Safety Precautions
To prevent personal injury, or property damage, read this section carefully before you use this product, and be sure to comply with the following
safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classi ed as follows:
This mark warns of death or serious injury.
This mark denotes an action that is PROHIBITED.
• Explanation of symbols displayed on the indoor unit or outdoor unit.
This symbol shows that this appliance uses a ammable refrigerant. If the refrigerant is leaked and exposure to an external
WARNING
ignition source, there is a risk of re.
CAUTION
This symbol shows that the Operation Manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this equipment with reference to the Installation Manual.
CAUTION
This symbol shows that information is available such as the Operating Manual or Installation Manual.
• The appliance shall be installed, operated and stored in a
room with a oor area larger than 2.06m
• The appliance contains no user-serviceable parts. Always
consult authorized service personnel for repairing, installation,
and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or re.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should only be replaced by authorized
service personnel.
• In the event of refrigerant leakage, be sure to keep away
from re or any ammables, and consult authorized service
personnel.
• In the event of a thunder storm or any prior sign of a lightning
strike, turn off the air conditioner via the remote controller,
and refrain from touching the product or the power source to
prevent any electrical hazards.
PART No. 9320455088
R32
REFRIGERANT
This Air Conditioner contains and
operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
WARNING
2
.
OPERATING MANUAL
Contents
Safety Precautions ..........................................................En-1
Indoor Unit Overview and Operations .............................En-3
Timer Operation...............................................................En-6
Human Sensor (Energy Saving) ......................................En-8
General Information on Operation ...................................En-9
Care and Cleaning.........................................................En-10
Troubleshooting .............................................................En-12
This mark warns of injury or damage to property.
This mark denotes an action that is COMPULSORY.
WARNING
• The appliance shall be stored in a room without continuously
operating ignition sources (for example: open ames, an
operating gas appliance or an operating electric heater).
• The appliance shall be stored in a well-ventilated area.
• Be aware that refrigerants may not contain an odour.
• The appliance shall be stored so as to prevent mechanical
damage from occurring.
• Disposing of the product shall be done properly, in
compliance with national or regional regulations.
• During transportation or relocation of the indoor unit, pipes
shall be covered with the wall hook bracket for protection.
Do not move the appliance by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
ammable gas to leak during operation).
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of
the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play
with the appliance.
CAUTION
(continued)
En-1
loading

Summary of Contents for Fujitsu ASTG18CMCB

  • Page 1: Table Of Contents

    Demand Response and Indoor Unit Operation ....En-8 General Information on Operation ........En-9 Care and Cleaning............En-10 Troubleshooting .............En-12 ASTG18CMCB ASTG24CMCB Before using this product, read these instructions thoroughly and keep this manual for future reference. Safety Precautions To prevent personal injury, or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions.
  • Page 2 Safety Precautions (continued) WARNING • Do not install the unit in area lled with mineral oil such as a • Do not insert your ngers or any other objects into outlet factory or area containing a large amount of splashed oil or port, open panel, or intake grille.
  • Page 3: Indoor Unit Overview And Operations

    AIR CONDITIONER Wall Mounted Type Indoor Unit Overview and Operations CAUTION Intake grille For appropriate signal transmission between remote controller and Before starting operation, make sure that the intake grille has been indoor unit, keep the signal receiver away from the following items: shut completely.
  • Page 4: Remote Controller Overview And Operations

    Remote Controller Overview and Operations CAUTION • To prevent malfunction or damage of the remote controller: • If leaking battery uid comes in contact with your skin, eyes, or mouth, immediately rinse with plenty of clean water, and - Place remote controller at where will not be exposed to consult your physician.
  • Page 5 AIR CONDITIONER Wall Mounted Type Remote Controller Overview and Operations (continued) Signal transmitter 18 TEST RUN button Aim at the signal receiver of the indoor unit properly. Only used for the initial test in the unit installation. • Signal transmit indicator on the remote controller display shows Do not press this button under normal use because it will cause that the signal from the remote controller is being transmitted.
  • Page 6: Timer Operation

    Timer Operation Remote controller custom code setting Note for timer settings: Any interruption of the power supply, such as a blackout or cutting off When two or more air conditioners are installed in a room and the of a circuit breaker, makes the set internal clock go wrong. remote controller is operating an air conditioner other than the one you In such a case, the TIMER indicator on the indoor unit blinks, and you wish to set, change the custom code of the remote controller to operate...
  • Page 7 AIR CONDITIONER Wall Mounted Type Timer Operation (continued) To set the WEEKLY timer, rst follow steps ①~③ on page 6 for WEEKLY timer the ON/OFF timer. ON and OFF timer can be combined, and up to 4 reservations (program Select the program number and the day using the SELECT ) per day and 28 reservations per week.
  • Page 8: Human Sensor (Energy Saving

    If the air conditioner is under demand controlling, consult the issues with your electricity supplier. If they are not demand controlling the air conditioner, refer to your warranty card for the contact details of Fujitsu General (AUST.) PTY LIMITED or visit our website : www.fujitsugeneral.com.au En-8...
  • Page 9: General Information On Operation

    AIR CONDITIONER Wall Mounted Type General Information on Operation Auto-restart function In event of power interruption such as a blackout, the air conditioner stops once. But it restarts automatically and performs previous operation when the power supply is resumed. If any power interruption occurs after the timer is set, counting down of the timer will be reset.
  • Page 10: Care And Cleaning

    Care and Cleaning CAUTION • Before cleaning this product, be sure to turn it off and disconnect all the power supply. • Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an effect on the proper working or performance of the air conditioner.
  • Page 11 AIR CONDITIONER Wall Mounted Type Care and Cleaning (continued) Following 2 types of air cleaning lters are used in this product. Replacing the air cleaning lters When you replace them, purchase dedicated air cleaning lters for this Remove the air lter. (Refer to step 1 and 2 in “Cleaning the air product.
  • Page 12: Troubleshooting

    Troubleshooting WARNING In following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel. As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off. •...