Gain Switching Function - Panasonic MINAS A5-series Operating Instructions Manual

Minas a5-series ac servo motor and driver
Table of Contents
5
Adjustment
By selecting appropriate gain based on internal data or external signal, the following ef-
fects can be obtained.
• Decrease the gain at the time of stoppage (servo lock) to reduce vibration.
• Increase the gain at the time of stoppage (setting) to shorten the settling time.
• Increase the gain during operation to improve command compliance.
• Based on condition of the equipment, change the gain with external signal.
Action
Status
Gain
Following is the example when you want to reduce the noise at motor in stall (Servo-Lock),
by setting up to lower gain after the motor stops.
• Make adjustment referring to the basic gain parameter setup table (P.5-9) as well.
Parameter
No.
Title of parameter
(Pr
)
1st gain of position loop
1.00
1st gain of velocity loop
1.01
1st time constant of velocity integration
1.02
1.03
1st filter of velocity detection
1st time constant of torque filter
1.04
Velocity feed forward
1.10
Filter of velocity feed forward
1.11
2nd gain of position loop
1.05
2nd gain of velocity loop
1.06
2nd time constant of velocity integration
1.07
1.08
2nd filter of velocity detection
2nd time constant of torque filter time
1.09
Action setup of 2nd gain
1.14
1st mode of control switching
1.15
1st delay time of control switching
1.16
1st level of control switching
1.17
1st hysteresis of control switching
1.18
1.19
Switching time of position gain
Inertia ration
0.04
Related page
• P.4-5... "Details of parameter"
4. Manual Gain Tuning (Basic)
Gain Switching Function
Command speed
Stop
Run
(Servo-Lock)
Low gain
High gain
(1st gain)
(2nd gain)
1ms
Suppress the vibration by lowering the gain.
Execute manual
gain-tuning
without gain
switching
630
350
160
0
65
300
50
0
• Enter the known
value from load
calculation
• Measure the
inertia ratio by
executing nor
mal auto-gain
tuning
• Default is 250
Stop
Time
(Servo-Lock)
Low gain
(1st gain)
2ms
Set up the same
Set up Pr1.05 to
value as Pr1.05
to 1.09 (1st gain)
(Gain switching
condition)
to Pr1.00 to 1.04
(2nd gain)
630
350
160
0
65
Adjust Pr1.01
1.09
and 1.04 at
stopping
(1st gain)
270
84
1
7
30
0
0
0
5-17
1
2
3
4
5
6
7
Table of Contents
loading