Unit installation

7.1.3 Installation site requirements of the indoor unit

Installer reference guide
68
INFORMATION
Also read the precautions and requirements in the
precautions" [
4
The indoor unit is designed for indoor installation only and for the following
ambient temperatures:
-
Space heating operation: 5~30°C
-
Space cooling operation: 5~35°C
-
Domestic hot water production: 5~35°C
INFORMATION
Cooling is only applicable in case of reversible models.
Mind the measurement guidelines:
Maximum refrigerant piping length
outdoor unit
Minimum refrigerant piping length
outdoor unit
Maximum height difference between indoor unit and outdoor unit:
When outdoor unit (ERGA06E▲V3H▼ or
ERGA08E▲V3H▼) is at highest location
When outdoor unit (ERGA04E▲V3▼ or
ERGA04~08E▲V3A▼) is at highest location
When indoor unit is at highest location
Maximum distance between the 3‑way valve and the indoor
unit (for installations with domestic hot water tank)
Maximum distance between the domestic hot water tank and
the indoor unit (for installations with domestic hot water tank)
(a)
Refrigerant piping length is the one-way length of liquid piping.
Mind the following spacing installation guidelines:
≥450
H Height measured from the bottom of the casing to the floor
Additionally to the spacing guidelines: The room where you install the indoor unit
must also comply with the conditions described in
4
patterns" [
 69].
 10].
(a)
between indoor unit and
(a)
between indoor unit and
≥500
(mm)
"2  General safety
30 m
3 m
30 m
20 m
20 m
3 m
10 m
"7.1.5  Installation
ERGA04~08E + EHBH/X04+08E
Daikin Altherma 3 R W