10
|
Configuration
Quiet
Installer reference guide
200
To configure the holiday
1 Activate the holiday mode.
Go to [7.3.1]: User settings > Holiday > Activation.
7.3.1
Activation
From
Till
Select On.
2 Set the first day of your holiday.
Go to [7.3.2]: From.
Select a date.
Confirm the changes.
3 Set the last day of your holiday.
Go to [7.3.3]: Till.
Select a date.
Confirm the changes.
About quiet mode
You can use quiet mode to decrease the sound of the outdoor unit. However, this
also decreases the heating/cooling capacity of the system. There are multiple quiet
mode levels.
The installer can:
Completely deactivate quiet mode
Manually activate a quiet mode level
Enable the user to program a quiet mode schedule
Configure restrictions based on local regulations
If enabled by the installer, the user can program a quiet mode schedule.
INFORMATION
If the outdoor temperature is below zero, we recommend to NOT use the most quiet
level.
To check if quiet mode is active
If
is displayed on the home screen, quiet mode is active.
To use quiet mode
1 Go to [7.4.1]: User settings > Quiet > Mode.
2 Do one of the following:
ERGA04~08E + EHBH/X04+08E