Daikin Altherma 3 R W Installer's Reference Manual page 290

Hide thumbs Also See for Altherma 3 R W:
Table of Contents
8/11
Field settings table
Breadcrumb Field code
Setting name
9.I
[4-01]
Which electric heater has priority?
9.I
[4-02]
Below which outdoor temperature is heating allowed?
9.I
[4-03]
Operation permission of the booster heater.
9.I
[4-04]
Water pipe freeze prevention
9.I
[4-05]
--
9.I
[4-06]
Emergency
9.I
[4-07]
--
9.I
[4-08]
Which power limitation mode is required on the system?
9.I
[4-09]
Which power limitation type is required?
9.I
[4-0A]
Backup heater configuration
9.I
[4-0B]
Automatic cooling/heating changeover hysteresis.
9.I
[4-0D]
Automatic cooling/heating changeover offset.
9.I
[4-0E]
--
9.I
[5-00]
Equilibrium: Deactivate backup heater (or external backup heat source in case of a
bivalent system) above the equilibrium temperature for space heating?
9.I
[5-01]
What is the equilibrium temperature for the building?
9.I
[5-02]
Space heating priority.
9.I
[5-03]
Space heating priority temperature.
9.I
[5-04]
Set point correction for domestic hot water temperature.
9.I
[5-05]
What is the requested limit for DI1?
9.I
[5-06]
What is the requested limit for DI2?
9.I
[5-07]
What is the requested limit for DI3?
9.I
[5-08]
What is the requested limit for DI4?
9.I
[5-09]
What is the requested limit for DI1?
9.I
[5-0A]
What is the requested limit for DI2?
9.I
[5-0B]
What is the requested limit for DI3?
9.I
[5-0C]
What is the requested limit for DI4?
9.I
[5-0D]
Backup heater voltage
9.I
[5-0E]
--
9.I
[6-00]
The temperature difference determining the heat pump ON temperature.
9.I
[6-01]
The temperature difference determining the heat pump OFF temperature.
9.I
[6-02]
What is the capacity of the booster heater?
9.I
[6-03]
What is the capacity of the backup heater step 1?
9.I
[6-04]
What is the capacity of the backup heater step 2?
9.I
[6-05]
--
9.I
[6-06]
--
9.I
[6-07]
What is the capacity of the bottom plate heater?
9.I
[6-08]
What is the hysteresis to be used in reheat mode?
9.I
[6-09]
--
9.I
[6-0A]
What is the desired comfort storage temperature?
9.I
[6-0B]
What is the desired eco storage temperature?
9.I
[6-0C]
What is the desired reheat temperature?
9.I
[6-0D]
What is the desired DHW production type?
9.I
[6-0E]
What is the maximum temperature setpoint?
9.I
[7-00]
Domestic hot water booster heater overshoot temperature.
9.I
[7-01]
Domestic hot water booster heater hysteresis.
4P629091-1B - 2021.02
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W (*2)
R/O (*1)
(*3)
R/W
R/W
R/W
R/W
R/O (*1)
R/W (*2)
(*3)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
(#) Setting is not applicable for this unit.
Range, step
Default value
0: None
1: BSH
2: BUH
14~35°C, step: 1°C
22°C
0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Legionella only
0: Intermittent
1: Continuous
2: Off
0
0: Manual
1: Automatic(normal SH/DHW ON)
2: Auto red SH/DHW ON
3: Auto red SH/DHW OFF
4: SH ON/DHW OFF
6
0: No limitation
1: Continuous
2: Digital inputs
0: Current
1: Power
0: 1 (*1)
1: 1/1+2 (*2) (*3)
2: 1/2
3: 1/2 + 1/1+2 in emergency
1~10°C, step: 0,5°C
1°C
1~10°C, step: 0,5°C
3°C
6
0: No
1: Yes
-15~35°C, step: 1°C
0°C
0: Disabled
1: Enabled
-15~35°C, step: 1°C
0°C
0~20°C, step: 1°C
10°C
0~50 A, step: 1 A
50 A
0~50 A, step: 1 A
50 A
0~50 A, step: 1 A
50 A
0~50 A, step: 1 A
50 A
0~20 kW, step: 0,5 kW
20 kW
0~20 kW, step: 0,5 kW
20 kW
0~20 kW, step: 0,5 kW
20 kW
0~20 kW, step: 0,5 kW
20 kW
0: 230V, 1~ (*1) (*2)
1: 230V, 3~ (*2)
2: 400V, 3~ (*3)
1
2~40°C, step: 1°C
25°C
0~10°C, step: 1°C
2°C
0~10kW, step: 0,2kW
3kW
0~10kW, step: 0,2kW
2kW (*2)
3kW (*1)(*3)
0~10kW, step: 0,2kW
0kW (*1)
4kW (*2)
6kW (*3)
0
0
0~200W, step: 10W
0W
2~20°C, step: 1°C
10°C
0
30~[6-0E]°C, step: 1°C
60°C
30~min(50, [6-0E])°C, step: 1°C
45°C
30~min(50, [6-0E])°C, step: 1°C
45°C
0: Reheat only
1: Reheat + sched.
2: Scheduled only
(*4) : 40~75°C, step: 1°C
60°C [E-07]=0
(*4) : 40~80°C, step: 1°C
80°C [E-07]=5
(*5) : 40~60°C, step: 1°C
60°C
0~4°C, step: 1°C
0°C
2~40°C, step: 1°C
2°C
Installer setting at variance with
default value
Date
Value
(*1) *3V_(*2) *6V_