PACMotion™ PSD Installation and User Manual
GFK-3168A
5.10.3
24 V auxiliary supply (X1)
The following diagram describes external 24 VDC power supply, electrically isolated, for example,
via an isolating transformer. The required current rating depends on the use of motor brake card
(➜ # 36) or (➜ # 37).
Figure 33: 24V Auxiliary Supply
5.10.3.1
IC830DP003 to 024, connector X1
Mechanical Installation
Pin
Signal
1
+24
2
GND
3
STO
Description
+24 VDC Auxiliary voltage
24V Supply GND
STO enable (Safe Torque Off)
Section 5
September 2020
71