Bosch WORCESTER Sense II Installation Instructions Manual page 22

Advanced weather compensation controller
Table of Contents
Commissioning
Menu item
Start configuration wizard
System data
Low loss hdr.
sensr. instll.
Config. DHW
at boiler
Config. of HC1
at boiler
Min. outdoor
temperature
Type of
building
Boiler data
Pump type
Pump run-on
time
Heating circuit 1 Heating circuit
installed
Ctrl type h.
circ. 1
Prog. unit
heat. circ. 1
Heating
system heat
circ. 1
Set point
constant
Max. flow
temperature
Set heating
curve
Table 14 Commissioning with the configuration wizard
22
Question
Check before starting the configuration wizard:
Module installed and coding address set (E.g.
MS100)?
Remote control installed and set (E.g. Sense I)?
Temperature sensor installed (e.g. solar collector,
low loss header or DHW sensor)?
Start the configuration wizard?
Is a low loss header installed? If yes, is a temperature
sensor installed? If yes, where is it electrically
connected to?
How is DHW connected to the heat source (boiler)?
Is heating circuit 1 connected to the heat source
(boiler)? If yes, does the heating circuit rely on the
boiler pump (no own heating circuit pump) or a
separate, dedicated heating circuit pump (own
pump)?
With weather-compensated control: What is the
minimum outside temperature at the location
averaged over the last years?
How well insulated is the building?
Is the pump operated depending on the burner output
or by differential pressure?
How long should the pump over-run be in order to
discharge the heat from the heat source?
Is heating circuit 1 installed? If yes, where is heating
circuit 1 electrically connected?
How should the temperature influencing heating
circuit 1 be controlled?
What controller is installed?
What type of heat emitter does heating circuit 1
operate with?
If heating circuit 1 is configured as constant heating
circuit: To what temperature should the heating be
controlled?
What is the maximum flow temperature that should be
set?
Should the heating curve for heating circuit 1 be set?
(For further sub-settings  Chapter 7.1.3, starting on
page 33)
Answer/setting
Yes | No
No low-loss header | At the
boiler | At the module | Header w/
o sensor
No DHW | 3-way valve | Primary
pump
No heating circuit | No own
heating circuit pump | Own pump
– 35 – 10 °C
Light | Medium | Heavy
Output-compensated | Delta P-
compensated 1 – 4
24h | 1 – 60 min
No | At the boiler | At the module
Outdoor-temp.-compensated |
Outside temp. with low end |
Room-temp.-compensated |
Room temperature output |
Constant
Sense II | Sense I
Radiator | Convector heater |
Underfloor
30 – 85 °C
For example 30 – 85 °C
 page 36, Tab. 21
Sense II – 6 720 818 367 (2015/10)