Using Weather-Dependent Curves; Settings Menu; Malfunction; Room - Daikin Altherma 3 GEO Series Installer's Reference Manual

Hide thumbs Also See for Altherma 3 GEO Series:
Table of Contents
10 Configuration
Item
Y1, Y2,
Examples of desired tank temperature or leaving water
Y3, Y4
temperature. The icon corresponds to the heat emitter
for that zone:
: Underfloor heating
: Fan coil unit
: Radiator
: Domestic hot water tank
Possible actions on this screen
Select slope or offset.
Increase or decrease the slope/offset.
When slope is selected: set slope and go to offset.
When offset is selected: set offset.
Confirm changes and return to the submenu.
10.4.4

Using weather-dependent curves

Configure weather-dependent curves as following:
To define the setpoint mode
To use the weather-dependent curve, you need to define the correct
setpoint mode:
Go to setpoint mode ...
Main zone – Heating
[2.4] Main zone > Setpoint
mode
Main zone – Cooling
[2.4] Main zone > Setpoint
mode
Additional zone – Heating
[3.4] Additional zone >
Setpoint mode
Additional zone – Cooling
[3.4] Additional zone >
Setpoint mode
Tank
[5.B] Tank > Setpoint mode
To change the type of weather-dependent curve
To change the type for all zones and for the tank, go to [2.E] Main
zone > WD curve type.
Viewing which type is selected is also possible via:
▪ [3.C] Additional zone > WD curve type
▪ [5.E] Tank > WD curve type
To change the weather-dependent curve
Zone
Main zone – Heating
Main zone – Cooling
Additional zone – Heating
Additional zone – Cooling
Tank
Installer reference guide
62
Description
Set the setpoint mode to ...
WD heating, fixed cooling
OR Weather dependent
Weather dependent
WD heating, fixed cooling
OR Weather dependent
Weather dependent
Weather dependent
Go to ...
[2.5] Main zone > Heating WD
curve
[2.6] Main zone > Cooling WD
curve
[3.5] Additional zone >
Heating WD curve
[3.6] Additional zone >
Cooling WD curve
[5.C] Tank > WD curve
INFORMATION
Maximum and minimum setpoints
You cannot configure the curve with temperatures that are
higher or lower than the set maximum and minimum
setpoints for that zone or for the tank. When the maximum
or minimum setpoint is reached, the curve flattens out.
To fine-tune the weather-dependent curve: slope-offset curve
The following table describes how to fine-tune the weather-
dependent curve of a zone or tank:
You feel ...
At regular outdoor
At cold outdoor
temperatures ...
temperatures ...
OK
Cold
OK
Hot
Cold
OK
Cold
Cold
Cold
Hot
Hot
OK
Hot
Cold
Hot
Hot
To fine-tune the weather-dependent curve: 2-points curve
The following table describes how to fine-tune the weather-
dependent curve of a zone or tank:
You feel ...
At regular outdoor
At cold outdoor
temperatures ...
temperatures ...
OK
Cold
OK
Hot
Cold
OK
Cold
Cold
Cold
Hot
Hot
OK
Hot
Cold
Hot
Hot
(a)
See
"10.4.2 2-points
10.5

Settings menu

You can set additional settings using the main menu screen and its
submenus. The most important settings are presented here.
10.5.1

Malfunction

In case of a malfunction,
or
If you open the menu screen, the Malfunctioning menu will now
be visible. Open the menu to see the error code. Press
information about the error.
10.5.2

Room

Setpoint screen
You can control the room temperature of the main zone with the
setpoint screen, also see
"10.3.5 Setpoint
Schedule
In this menu item you can indicate if the room temperature is
controlled with a schedule or not.
Fine-tune with slope and
offset:
Slope
Offset
Fine-tune with
setpoints:
(a)
(a)
(a)
(a)
Y2
Y1
X1
X2
curve" [ 4  61].
will appear on the home screen.
to get more
screen" [ 4  58].
EGSAH/X06+10DA9W(G)
Daikin Altherma 3 GEO
4P569820-1A – 2019.09

Hide quick links:

Table of Contents
loading

Table of Contents