9.3 Hazardous Locations Certifications

AGENCY
TYPE OF PROTECTION
Explosion Proof with
intrinsically safe probe:
Class I, Division 1, Groups A, B, C,
D;
Class I, Zone 0/1 AEx d[ia] IIC T4
Ga/Gb
Ex d[ia] IIC T4 Ga/Gb
Dust Ignition Proof:
Class II, III, Division 1, Groups E,
F, G; T4
Class II Zone 21 AEx tb IIIC T95
o
CSA
DIP A21/II, III /1/EFG/Ex tb IIIC
cCSAus
T95
(Canada and
USA)
Intrinsically Safe:
Class I, II, III, Division 1, Groups A,
B, C, D, E, F, G; T4
Certificate #
70016542
Class 1 Zone 0 AEx ia IIC T4 Ga
Ex ia IIC T4 Ga
Non-incendive with intrinsically
safe probe:
Class I, Division 2, Groups A, B, C,
D; T4
Class I, Zone 0/2 AEx nA[ia] IIC T4
Ga/Gc
Ex nA[ia] IIC T4 Ga/Gc
Enclosure: Type 4X/ IP66/ IP67.
Dual Seal in accordance with
ANSI/ISA 12.27.01
Canadian Registration Number (CRN):
Revision 7