EAN/JAN-8 Addenda Required
When Required is scanned, the scanner will only read EAN/JAN-8 bar codes that
have addenda. Default = Not Required.

Addenda Timeout

You can set a time during which the scanner looks for an addenda. If an addenda is
not found within this time period, the data can be either transmitted or discarded,
based on the setting you are using for
length (in milliseconds) for this timeout by scanning the bar code below, then set-
ting the timeout (from 0-65535 milliseconds) by scanning digits from the
Programming
Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
EAN/JAN-8 Addenda Separator
When this feature is On, there is a space between the data from the bar code and
the data from the addenda. When turned Off, there is no space. Default = On.

EAN/JAN-8 Redundancy

If you are encountering errors when reading EAN/JAN-8 bar codes, you may want
to adjust the redundancy count. Redundancy adjusts the number of times a bar
code is decoded before transmission, which may reduce the number of errors. Note
that the higher the redundancy count, the longer it will take to decode the ba code.