Output Function - Hitachi IJ RX2 Technical Manual

Ink jet printer for industrial marking
Hide thumbs Also See for IJ RX2:
Table of Contents

4.3.4 Output function

The state of the IJ printer is monitored by connecting the print output ("Print-in-progress" or "Print.complete"),
online output, Ready, Fault, and Warning signals to pins 10 to 23 of TB1. (No-contact (transistor) output)
Internal circuit diagram
(a) NPN interface output (no-voltage output)
●The output transistor is open collector, and the logic is transistor ON at operation ON.
●The voltage and current used by the external equipment must satisfy the following specifications:
<
IL 20mA (V
=
<
Vd DC30V
=
●Wiring precautions
Load
●When the load is a relay, solenoid, or other inductive load, connect a diode to prevent generation of a
counter electromotive force in parallel with the load.
●The load circuit is DC dedicated. It cannot be used with an AC load.
(b) PNP interface output (voltage output)
●The output transistor is open collector and the logic is transistor ON (voltage output) at operation ON.
●When used with external equipment, the following shall be satisfied:
<
IL 10mA(V
=
Withstand voltage 50VDC or greater (2 times or more of the voltage used)
Vd
19
Print output
IL
Online output
20
V
GND
23
Ready
10
11
GND
12
Fault
13
Warning
: TYP0.6V, MAX2V)
CE
TB1
20
Online output
23
GND
19
Print output
R
IL
Online output
20
GND
23
: TYP0.6V, MAX2V), Guide line of R : R
CE
CE
*Other signals are also the same.
IJ printer
*Other signals are also the same.
24V
V
CE
IJ printer
> =
2.2kΩ
●Input/output (I/O) specifications 4-22