Quick Links

READ AND SAVE THESE INSTRUCTIONS
54" Ceiling Fan Owner's Manual
CF965BS00
CF965VNB00
Questions, problems, missing parts: Before returning to the store call
Part No. F40BP74980000
Revision: 150123
PORTLAND
Model Numbers
- Brushed Steel
Net Weight:
Emerson Electric Customer Service
8 a.m. - 6 p.m., Eastern, Monday-Friday
1-800-654-3545
www.emersonfans.com
- Venetian Bronze
25.9
Lbs.
• Español - página 33
• Français - page 65
Form No. BP7498
ETL Model No.: CF965
Table of Contents
loading

Summary of Contents for Emerson Portland CF965BS00

  • Page 1 - Venetian Bronze 25.9 Net Weight: Lbs. Questions, problems, missing parts: Before returning to the store call Emerson Electric Customer Service 8 a.m. - 6 p.m., Eastern, Monday-Friday • Español - página 33 1-800-654-3545 • Français - page 65 www.emersonfans.com Part No.
  • Page 2: Table Of Contents

    Electric Co. Substitution of parts or accessories not at the fuse box before wiring, and do not operate fan without blades. designated for use with this product by Emerson could result in personal injury or property damage. 2. All wiring must be in accordance with the National WARNING: To reduce the risk of personal injury, do not Electrical Code “ANSI/NFPA 70-2014”...
  • Page 3: Unpacking Instructions

    Emerson Electric Light Kit Assembly Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could Lower Glass Shade result in personal injury or property damage.
  • Page 4: Tools Needed For Assembly

    Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a Your Emerson ceiling fan comes supplied with a Fan/Light 3-conductor (2-wire with ground) of following size: Remote Control which consists of a receiver mounted Installed Wire Length Wire Size A.W.G.
  • Page 5: Ceiling Fan Assembly

    3. Ceiling Fan Assembly WARNING Turning off wall switch is not sufficient. To avoid possible Disconnect electrical power to the branch circuit at the electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in circuit breaker or fuse box before attempting to install the accordance with National and Local codes and the ceiling ceiling fan mounting plate on the outlet box.
  • Page 6 3. Ceiling Fan Assembly (Continued) 1/4-20 x 1/2" SLOTTED PHILLIPS HEAD SCREW AND LOCKWASHER Loosely attach one blade/flange assembly to the motor (2 per blade/flange assembly) hub by securing the two 1/4-20 x 1/2” slotted phillips head BLADE/FLANGE screws with lockwashers. Make sure the screws are NOT ASSEMBLY (5) tightened (Figure 3).
  • Page 7 3. Ceiling Fan Assembly (Continued) CEILING FAN STYROFOAM (partially assembled) Carefully turn the partially assembled ceiling fan over and NOTE: Be extra careful not to bend the ceiling fan place it on the styrofoam for final preparation (Figure 5). blades while turning the fan over onto the styrofoam. Figure 5 NOTE: If using a longer accessory downrod, discard the supplied 4.5"...
  • Page 8 3. Ceiling Fan Assembly (Continued) 3.11 HAIRPIN Loosen the two setscrews in the motor coupling. CLIP CLEVIS 4.5" Place the 4.5” downrod into the motor coupling, aligning DOWNROD the clevis pin holes in the downrod with the holes in the motor coupling (Figure 8).
  • Page 9 3. Ceiling Fan Assembly (Continued) 3.14 4.5" DOWNROD Place the ceiling cover over the downrod. CEILING Be sure the ceiling cover is oriented correctly COVER (Figure 11). Figure 11 3.15 4.5" DOWNROD Route the two 80” motor leads through the hanger ball. HANGER BALL Reinstall the hanger ball (Figure 12) on the downrod as follows:...
  • Page 10 3. Ceiling Fan Assembly (Continued) 3.17 RUBBER PAD AND CLAMP (4) Carefully place the upper glass onto the motor housing 3.18 LOWER HOUSING SCREWS (4) (Figure 14). Rotate the four lower housing clamps over the inner edge of the upper glass. Be sure to keep the rubber pad beneath each clamp to ensure proper clamping.
  • Page 11: How To Hang Your Ceiling Fan

    4. How to Hang Your Ceiling Fan WARNING CEILING The fan must be hung with at least 7' of clearance from floor to blades (Figure 15). AT LEAST FLOOR Figure 15 WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs.
  • Page 12 4. How to Hang Your Ceiling Fan (Continued) NOTE: CEILING COVER, SUPPL Y WIRES AND FAN WIRES OMITTED FOR CLARITY. Carefully lift the fan and seat the hanger ball/ downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 17). OUTLET Be sure the groove in the ball is engaged with the anti- rotation tab on the hanger bracket (Figure 17).
  • Page 13: How To Wire Your Ceiling Fan

    Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage. Securely connect the fan motor white wire to the supply...
  • Page 14 5. How to Wire Your Ceiling Fan (Continued) Securely connect the fan motor black wire to the supply black (hot) wire using wire connector (supplied) (Figure 20). SUPPLY BLACK (HOT) LISTED WIRE CONNECTOR FAN MOTOR BLACK WIRE Figure 20 After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and position GREEN...
  • Page 15 5. How to Wire Your Ceiling Fan (Continued) Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 22). THREADED STUDS (2) Figure 22 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 23).
  • Page 16: Installation Of Downlight

    6. Installation of Downlight Remove the pre-installed wire nut from the fan motor assembly white wire. Carefully straighten the white wire strands. Pair the light kit assembly white wire with the motor assembly white wire and install the previously removed wire nut (Figure 24). LIGHT KIT ASSEMBLY BLACK WIRE...
  • Page 17 6. Installation of Downlight (Continued) WARNING To avoid risk of burns or other injuries, turn power off and allow lamp to fully cool before attempting to replace the mini-halogen base bulbs. Screw the three 50-watt (maximum) mini-halogen base bulbs (supplied) in the light kit fixture sockets NOTE: Do not touch the halogen mini-halogen base (Figure 26).
  • Page 18: Optional Al100 Accent Light Installation

    7. Optional AL100 Accent Light Installation CAUTION: To reduce the risk of electrical shock, disconnect the electrical supply circuit before installing the accent light kit. GLASS LOWER HOUSING SHADE SCREWS (4) Loosen and remove all three pre-installed AL100 mounting screws from the upper housing of the motor assembly (Figure 28).
  • Page 19: Wall Control Procedures

    Code switches in the transmitter may be set in 32 different positions. If your fan and light turn on and off Your Emerson Ceiling Fan/Light Control consists of without using your control, you may be getting interference SW605 wall mounted transmitter and a receiver located from other remote units such as garage door openers, car inside the motor assembly.
  • Page 20: Wall Control Installation

    9. Wall Control Installation SINGLE-POLE INSTALLATION WARNING CAUTION: To reduce the risk of electrical shock, Turning off wall switch is not sufficient. To avoid possible disconnect the electrical supply circuit before electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring.
  • Page 21 9. Wall Control Installation (Continued) SCREWS (2) Before installing the SW605 wall control, place the SW605 SW605 FAN/LIGHT WALL CONTROL WALL wall control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position. Connect one black wire of the SW605 wall control to the “hot”...
  • Page 22 CONTROL WARNING FAN OFF FAN OFF PURCHASED CONTROL ® EMERSON EMERSON ® SEPARATELY Turning off wall switch is not sufficient. To avoid possible BLACK electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring...
  • Page 23 9. Wall Control Installation (Continued) 3-WAY WIRING DIAGRAM: STANDARD WIRING FOR EXISTING NEW CONSTRUCTION 3-WAY CONTROLS NOTE: Retrofit 3-way installations are likely to include two traveler wires between the two wall boxes. In new construction, only one traveler wire Is required (See Figure 35).
  • Page 24: Programming The Receiver Operating Frequency & High Speed Conditioning Of Fan Control

    10. Programming the Receiver Operating Frequency & High Speed Conditioning of Fan Control -- Important - Read This Section Carefully and Follow the High Speed Conditioning Instructions Closely -- 10.2 PROGRAMMING THE RECEIVER OPERATING FREQUENCY & HIGH SPEED CONDITIONING OF FAN CONTROL The fan will run for approximately 2 minutes in the upward IMPORTANT: Ceiling fan blades MUST be installed direction then reverse direction to down flow and run an...
  • Page 25: Using Your Ceiling Fan

    11. Using Your Ceiling Fan USING YOUR CEILING FAN (Figure 36) WARNING Fan installation must be completed, including the installation of the fan blades, before testing the SW605 Your SW605 wall control has full control of your fan and wall control. light.
  • Page 26: Maintenance

    Emerson Electric WARNING Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could The use of any other control not specifically approved for result in personal injury or property damage.
  • Page 27: Trouble Shooting

    15. Trouble Shooting WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2.
  • Page 28: Repair Parts

    16. Repair Parts ETL Model No.: CF965...
  • Page 29: How To Order Repair Parts

    16. Repair Parts Listing Model Numbers Description CF965BS00 CF965VNB00 Hanger Ball Assembly, Consisting of: 761655-17 761655-89 Hanger Bracket (1) — — Hanger Ball (1) — — 4.5” Downrod Assembly (1) — — Ceiling Canopy (1) 764603-BS 764603-VNB Upper Glass Shade (1) 764607-OM 764607-OM Motor Coupler Cover (1)
  • Page 30 Notes ETL Model No.: CF965...
  • Page 31: Ceiling Fan Limited Warranty

    What We Will Do To Correct Problems: If during the one (1) year warranty period the motor or any component or accessory of your Emerson Ceiling Fan is defective in materials or workmanship, or if during the expected lifetime of the Emerson Ceiling Fan (when used in accordance with the User Manual or other instructions) the motor is defective in materials or workmanship, you must contact Emerson during the applicable warranty period.
  • Page 32 Air Comfort Products DIVISION OF EmErSON ElEctrIc cO. 8100 W. Florissant • St. louis, mO 63136 Questions, problems, missing parts: Before returning to the store call Emerson Electric Customer Service 8 a.m. - 6 p.m., Eastern, Monday-Friday 1-800-654-3545 www.emersonfans.com Retain this manual for future use.

This manual is also suitable for:

Portland cf965vnb00

Table of Contents