Emerson PRIMA CF901BS00 Owner's Manual

Prima ceiling fan
Hide thumbs Also See for PRIMA CF901BS00:

Quick Links

READ AND SAVE THESE INSTRUCTIONS
Ceiling Fan Owner's Manual
CF901BS00
CF901CK00
CF901GES00
Part No. F40BP74460000
PRIMA
Model Numbers
20.3
Net Weight:
CF901ORB00
CF901VNB00
Lbs.
Form No. BP7446
U.L. Model No.: CF901
Table of Contents
loading

Summary of Contents for Emerson PRIMA CF901BS00

  • Page 1 READ AND SAVE THESE INSTRUCTIONS ™ PRIMA Ceiling Fan Owner's Manual Model Numbers CF901BS00 CF901ORB00 CF901CK00 CF901VNB00 CF901GES00 20.3 Net Weight: Lbs. Part No. F40BP74460000 Form No. BP7446 U.L. Model No.: CF901...
  • Page 2: Safety Instructions

    WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control, Model No. SW46/U.L. Model No. UC9020 manufactured by Rhine Electric Co., Ltd. WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
  • Page 3: Unpacking Instructions

    The upper foam pad serves as a holder for the fan accessories not designated for use with this product during the first stages of assembly. by Emerson Electric Co. could result in personal injury or property damage. j. LOOSE PARTS 1.
  • Page 4: Electrical Requirements

    Electrical Requirements Your new ceiling fan will require a grounded electrical WARNING supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and Turning off wall switch is not sufficient. To avoid capable of withstanding a load of at least 50 pounds.
  • Page 5 How to Put Your Ceiling Fan Together (continued) 3. Make sure the grommet is properly installed in the coupling cover, then slide the coupling cover on the DOWNROD SETSCREW downrod until it rests on the motor housing. Place HANGER the ceiling cover over the downrod. Be sure that BALL the ceiling cover and the coupling cover are both CEILING...
  • Page 6 How to Put Your Ceiling Fan Together (continued) 11. Engage the connector of the switch housing assembly with the motor connector (Figure 7). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connector latch closes properly.
  • Page 7: How To Hang Your Ceiling Fan

    How to Hang Your Ceiling Fan CEILING WARNING The fan must be hung with at least 7' of clearance from floor to blades (Figure 9). AT LEAST WARNING FLOOR The outlet box and joist must be securely mounted and Figure 9 capable of supporting at least 50 lbs.
  • Page 8: How To Wire Your Ceiling Fan

    OMITTED FOR CLARITY. Figure 12 insulation). Securely connect wires with wire connectors supplied. NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wiring. 2. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 12).
  • Page 9: Wall Control Installation

    Wall Control Installation The fan speed control is designed to operate only one ceiling fan, and not an accessory light kit. This wall control is rated for 1.2 amps at 120 volts. To avoid erratic speeds and possible damage to your ceiling fan, use this control only with the fan pull chain switch set to its high speed setting.
  • Page 10 4. Ceiling Fan Blades (see store or catalog). Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal WARNING injury or property damage. The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
  • Page 11: Maintenance

    Maintenance Abrasive cleaning agents are not required and should IMPORTANT CARE INSTRUCTIONS be avoided to prevent damage to finish. for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only WARNING maintenance that is needed. When cleaning, use only a soft brush or lint free cloth Do not use water when cleaning your ceiling fan.
  • Page 12: Repair Parts

    Repair Parts U.L. Model No.: CF901...
  • Page 13: How To Order Repair Parts

    Repair Parts Listing Model Numbers Description CF901BS00 CF901CK00 CF901GES00 CF901ORB00 CF901VNB00 Hanger Ball Assembly, 761655-17 761655-23 761655-35 761655-32 761655-89 Consisting of: Hanger Bracket — — — — — Hanger Ball — — — — — Downrod (4.5”) — — —...
  • Page 14 Notes U.L. Model No.: CF901...
  • Page 15: Limited Warranty

    If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and shipping of the product to Emerson Electric Co.
  • Page 16 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP74460000 Printed in China 12/11 Form No. BP7446 U.L. Model No.: CF901...

Table of Contents