Replacing A 2.5-Inch Hdd / Ssd Module; Preliminary Steps - Fujitsu PRIMERGY TX300 S8 Upgrade And Maintenance Manual

Table of Contents
Hard disk drives / solid state drives
7.2.8

Replacing a 2.5-inch HDD / SSD module

Customer Replaceable Unit
(CRU)
Tools: tool-less
V
CAUTION!
Only remove an HDD / SSD module during operation if the drive is
not currently being accessed. Observe the indicators on the
HDD / SSD module, as described in the "PRIMERGY
TX300 S8 / RX350 S8 Server" operating manual".
Under no circumstances should you remove an HDD / SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD / SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.2.8.1

Preliminary steps

"Locating the defective server" on page 57
Ê
Ê When working on a tower server, open the HDD bay cover as described in
section
"Removing accessible drive and HDD bay covers" on page
Ê Locate the defective HDD / SSD module as described in section
diagnostic indicators on the front" on page
Only applicable for removing intact HDD / SSD modules:
Ê Before removing a non-defective HDD / SSD module, put the drive into
"Offline" mode using your RAID configuration software.
214
Upgrade and Maintenance Manual
Average task duration:
5 minutes
60.
TX300 S8 / RX350 S8
77.
"Local

Hide quick links:

Table of Contents
loading

This manual is also suitable for:

Primergy rx350 s8

Table of Contents