found in the crossbar cable connected to port number 0R of XBU#0 mounted in
BB#1.
Date: Sep 08 14:10:25 JST 2016
Code: 80002100-007d20007811007811-150650000130049a00313000
Status: Alarm
FRU: /BB#1/XBU#0/CBL#0R,/BB#1/XBU#0,/BB#0/XBU#0
Msg: XB-XB interface link-up error
From the above error message and
Building Block
connection of the target crossbar cable.
In this example, "BB00-XBU0-0R" is the port number at the other end.
Affix labels to the crossbar cable.
2.
The replacement crossbar cable comes with the labels shown in
Write the connected port on these labels. For the crossbar cable, use LABEL-A to
LABEL-D.
492
Fujitsu SPARC M12-2/M12-2S Service Manual ・ January 2023
Occurred: Sep 08 14:10:12.925 JST 2016
"Appendix A Lists of Cable Connections in a
Configuration," identify the port number at the other end of the
Figure
19-3.