Table 5-7     Active/Cold Addition Procedure of Memory (continue d)
Work
Order
16
*1 If the CMUU has no memory installed, install memory before installing the CMUU in the SPARC M12-2S.
*2 If the memory was added to a SPARC M12-2S with no PCIe cards mounted, no diagnosis is necessary (because
diagnosis was performed in the previous step).
5.2.5
Active/Cold Addition Workflow of the PCI
Expansion Unit
You can perform active/cold addition of a PCI expansion unit in the following
configuration:
Configuration connecting two or more SPARC M12-2S units to a physical partition
Before adding the PCI expansion unit, mount it in the rack. (See "3.4 Mounting the
SPARC M12-2S and the PCI Expansion Unit in a Rack" in the Fujitsu SPARC M12-2S
Installation Guide.)
Table 5-8
Table 5-8     Active/Cold Addition Procedure of a PCI Expansion Unit
Work
Order
1
2
3
4
5
6
Task
Assigning the resources of the added
SPARC M12-2S to logical domains
shows the workflow for active/cold addition of a PCI expansion unit.
Task
Checking the operating condition of the
system
Checking the logical domain assignment
status of CPU resources mounted in the
SPARC M12-2S requiring maintenance
Checking the logical domain assignment
status of memory resources mounted in
the SPARC M12-2S requiring maintenance
Releasing the logical domain assignment
of PCIe cards mounted in the SPARC
M12-2S requiring maintenance
Releasing the SPARC M12-2S requiring
maintenance from the physical partition
Switching the mode switch on the OPNL
to Service
Reference
"3.2 Operations and Commands Related
to Logical Domain Configurations" in the
Fujitsu SPARC M12 and Fujitsu
M10/SPARC M10 Domain Configuration
Guide
Reference
"9.2.1 Checking the Operation Status of
Physical Partitions and Logical
"3.2.4 Checking the Assignment Status
of Resources" in the Fujitsu SPARC M12
and Fujitsu M10/SPARC M10 Domain
Configuration Guide
"3.2.4 Checking the Assignment Status
of Resources" in the Fujitsu SPARC M12
and Fujitsu M10/SPARC M10 Domain
Configuration Guide
"9.3 Releasing I/O Resources From a
Logical
Domain"
"9.4.3 Dynamically Releasing the
SPARC M12-2S From the Physical
Partition"
"2.3.2 OPNL Control
Function"
Chapter 5 FRU Addition Workflows
Domains"
161