Fujitsu Oracle SPARC M12-2 Service Manual page 355

Hide thumbs Also See for Oracle SPARC M12-2:
Table of Contents
*1 Enter the login password of the HTTPS server.
10.3
Adding the SPARC M12-2S to a
Building Block Configuration
Note - When adding the SPARC M12-2S due to a change in the building block configuration,
be sure to perform the procedure described below.
Note - To add a SPARC M12-2S with 64 GB DIMMs mounted, see "Notes on Memory" in the
latest version of the Fujitsu SPARC M12 Product Notes.
This section describes the procedure for adding the SPARC M12-2S to BB#2 of the
building block configuration.
The added SPARC M12-2S is incorporated into the building block configuration in
the factory-default state. When you add a newly purchased SPARC M12-2S, do not
connect power cords until instructed so. If the SPARC M12-2S to be added has been
used in another system, be sure to reset it to its factory-default state by using the
restoredefaults or initbb command and do not connect power cords until instructed
so.
To perform system-stopped/cold addition of the SPARC M12-2S to a building block
configuration, see
M12-2S."
For details on the commands used here, see the Fujitsu SPARC M12 and Fujitsu
M10/SPARC M10 XSCF Reference Manual of the XCP version used.
 
 
Check the operation status of the building block configuration.
1.
Log in to the master XSCF, and check the operation status of the building block
configuration by using the showboards command.
The following example shows that BB#00 and BB#01 are connected to the
building block configuration.
XSCF> showboards -a -v
PSB
R PPAR-ID(LSB) Assignment
---- - ------------ ----------- ---- ---- ---- ------- --------
00-0
00(00)
01-0
00(01)
 
XSCF>
2.
Set a BB-ID for the SPARC M12-2S.
"5.6.6 System-Stopped/Cold Addition Workflow of the SPARC
Pwr
Conn Conf Test
Assigned
y
y
Assigned
y
y
Fault
y
Passed
Normal
y
Passed
Normal
Chapter 10 Setting Up the System
333