Installing the PW-6000 Two-Reader Module

Installing the Module

Installing the Module
1. Set Jumpers and DIP switches.
2. Mount this board in the appropriate enclosure - If this board is being mounted in a rack, the
3. Connect the communications and power supply to the circuit boards with the Power Supply
Warning: DO NOT CONNECT THE POWER SUPPLY TO THE AC SOCKET UNTIL ALL WIRING HAS
BEEN INSTALLED AND RECHECKED
4. Connect wiring to the reader interfaces as appropriate.
5. Connect wiring to input sensors or install jumper wire as appropriate.
6. Connect relay output wiring as appropriate.
7. Connect communications wiring to the Intelligent Controller.
8. Recheck wiring for correct connections and continuity.
9. When all boards have been installed, connect the power supply cord for proper connections and
10.Set up the panel controls using the host software.
14
component side of the board is to your right as you face the rack.
Harness.
power.
.
www.honeywell.com