Fujitsu PRIMERGY RX2450 M1 Upgrade And Maintenance Manual page 196

Table of Contents
System board and components
Figure 158: Position of screws and stand-offs
▶ Remove the two stand-offs (see orange circles) from the system board.
▶ Remove the nine screws (see blue circles) from the system board.
▶ Use both hands to lift the system board carefully out of the chassis in a
slight angle. Thereby you pull the connectors out of the I/O panel.
CAUTION
Always take the system board with both hands!
Never lift the system board one-sided or at a heat sink,
because the solder connections between the socket and the
system board come under tension and increase the risk of
damage and malfunction!
Do not damage the EMI springs which are essential to comply
with applicable EMC regulations and satisfy cooling
requirements and fire protection measures.
▶ Place the removed and the new system board on an antistatic surface.
196
Upgrade and Maintenance Manual
RX2450 M1