Fujitsu PRIMERGY RX2520 M5 Operating Manual

Fujitsu PRIMERGY RX2520 M5 Operating Manual

Hide thumbs Also See for PRIMERGY RX2520 M5:
Table of Contents

Quick Links

Questo manuale d'istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per
RX2520 M5 LKN:R2525SC210IN
Operating Manual - English
FUJITSU Server PRIMERGY RX2520 M5
Operating Manual
June 2019
o cerca il tuo prodotto tra le
migliori offerte di Server
Fujitsu PRIMERGY
Table of Contents
loading

Summary of Contents for Fujitsu PRIMERGY RX2520 M5

  • Page 1 Questo manuale d’istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per Fujitsu PRIMERGY RX2520 M5 LKN:R2525SC210IN o cerca il tuo prodotto tra le migliori offerte di Server Operating Manual - English FUJITSU Server PRIMERGY RX2520 M5 Operating Manual June 2019...
  • Page 2 – The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. – No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.
  • Page 3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure that these safety notes are understood before using the product.
  • Page 4 Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning.
  • Page 5: Table Of Contents

    Contents Introduction ......9 Notational conventions ..... 9 Before you start .
  • Page 6 Contents Environmental protection ....49 Starting up ......51 Installation steps, overview .
  • Page 7 Contents 6.2.1.2 Installing a 3.5-inch HDD module ....74 6.2.2 Installing 2.5-inch HDD/SSD modules ....76 6.2.2.1 Removing a 2.5-inch HDD/SSD dummy module .
  • Page 8 Contents Operating Manual RX2520 M5...
  • Page 9: Introduction

    This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. It contains all the information you need to put your PRIMERGY RX2520 M5 into operation. To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system.
  • Page 10 Introduction Operating Manual RX2520 M5...
  • Page 11: Before You Start

    Documentation overview To get an overview on all documents for your server, see the following table. All documentation on PRIMERGY hardware and ServerView software is available online from the Fujitsu manuals server at: http://manuals.ts.fujitsu.com For Japan: http://www.fujitsu.com/jp/products/computing/servers/primergy/manual/ The complete PRIMERGY documentation set can also be downloaded as a DVD ISO image at: ftp://ftp.ts.fujitsu.com/images/serverview/manuals...
  • Page 12 Management (eLCM)" user guide Illustrated Spares catalog Spare parts identification and information system (not valid for Japan), available for online use or download (Windows OS) at http://manuals.ts.fujitsu.com/illustrated_sp ares or from the CSS component view of the ServerView Operations Manager Glossary...
  • Page 13 Description "Returning used devices" Recycling and contact information, manual available online at http://ts.fujitsu.com/recycling, or as a "Service Desk" leaflet printed copy " サポー ト &サービ ス " for Japan Not applicable in Japan and other countries that have different regulations for recycling...
  • Page 14 Before you start Operating Manual RX2520 M5...
  • Page 15: Product Description

    Product description This section provides an overview of the server and information on the features of the PRIMERGY RX2520 M5 server. The PRIMERGY RX2520 M5 server is available as a rack model. Overview of the server 3.1.1 Server front 3.1.1.1 3.5-inch HDD versions...
  • Page 16: Inch Hdd/Ssd Versions

    Product description 3.1.1.2 2.5-inch HDD/SSD versions Figure 3: Front side 2.5-inch HDDs/SSDs (up to 16 HDDs/SSDs) Figure 4: Front side 2.5-inch HDDs/SSDs (up to 24 HDDs/SSDs) Pos. Component Front panel module ID card ODD (option) / dummy cover Bay for LTO/RDX drive (option) Bays for HDDs/SSDs (depending on the configuration) Front panel on QRL Operating Manual...
  • Page 17: Features

    – System fans – Expansion cards (not allowed in Japan) For more information on replacing these components, see the "FUJITSU Server PRIMERGY RX2520 M5 Upgrade and Maintenance Manual". CSS indicators on the front panel and I/O panel of the PRIMERGY server provide you with information if a CSS event arises.
  • Page 18 Product description System board The features of the system board are described in the "FUJITSU Server PRIMERGY RX2520 M5 Upgrade and Maintenance Manual". The setup possibilities are described in the "D3386 BIOS Setup Utility for FUJITSU Server PRIMERGY RX2520 M5 Reference Manual".
  • Page 19 "hides" the defective system components. The Prefailure Detection and Analysis (PDA) technology from Fujitsu analyzes and monitors all components that are critical for system reliability. A RAID controller supports different RAID levels and increase the availability and data security of the system.
  • Page 20 Internal Event Log for user login / logout auditing ● More information about the iRMC S5 can be found in the iRMC S5 user guides (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Out-Of-Band Management). Operating Manual...
  • Page 21 Product description Server management Server management is implemented using the ServerView Operations Manager supplied and the PDA technology from Fujitsu. PDA reports the threat of a system error or overload at an early stage, allowing preventive measures to be taken.
  • Page 22 (memory module, CPU, fan or expansion card) is not functioning properly. The Flash EPROM program supplied with the Fujitsu utilities supports a fast BIOS update. With the iRMC on the system board, the server can also be maintained and serviced remotely.
  • Page 23 By combining these options, you can also achieve optimum protection for your system. A detailed description of the Security menu and how to assign passwords can be found in the "D3386 BIOS Setup Utility for FUJITSU Server PRIMERGY RX2520 M5 Reference Manual". Operating Manual...
  • Page 24: Connectors, Controls And Indicators

    Product description Connectors, controls and indicators 3.3.1 Connectors on the server 3.3.1.1 Server front Figure 5: Connectors on the front panel module 2x USB 3.0 connectors 12x 3.5-inch HDD version and 24x 2.5-inch HDD/SSD version For this versions there is an USB 2.0 connector on the front panel on QRL instead of the two above mentioned USB3.0 connectors.
  • Page 25: Server Rear

    Product description 3.3.1.2 Server rear Figure 7: Connectors on the I/O panel No. Description COM1 connector (optional, can be used as the standard interface or for communication with iRMC) Shared LAN connector (LAN1) LAN connector (LAN2) 2x USB 3.0 connector 2x USB 3.0 connector Video connector (VGA) Management LAN connector (for iRMC S5 server management function)
  • Page 26: Controls And Indicators On The Server Front

    Product description 3.3.2 Controls and indicators on the server front 3.3.2.1 Controls on the front panel Figure 8: Controls on the front panel module Figure 9: Controls on the front panel on QRL Pos. Label Button Function Reboots the system. Press the reset button with a straightened end of a paper clip.
  • Page 27 Product description Pos. Label Button Function Used to troubleshoot software and device driver errors. Press the NMI button with a straightened end of a paper clip. NMI button CAUTION! Use this button only if directed to do so by qualified certified maintenance personnel! Highlights the ID indicator on the front panel ID button...
  • Page 28: Indicators On The Front Panel

    Product description 3.3.2.2 Indicators on the front panel Figure 10: Indicators on the front panel module Figure 11: Indicators on the front panel on QRL Pos. Label Indicator Status Description The server has been highlighted using ServerView Operations indicator, blue on Manager, iRMC web interface or the see also ID button on the front panel for easy...
  • Page 29 Product description Pos. Label Indicator Status Description No critical event detected (CSS component). Prefailure event detected (CSS component). orange [CSS] For HDDs/SSDs, see also indicator "HDD/SSD prefailure detection" on page flashing CSS component failure detected. orange No critical event detected (non CSS component).
  • Page 30 An emergency flash of the iRMC firmware is in progress. For more information on the flashing blue flashing orange emergency flash of the iRMC firmware, see the "FUJITSU Server PRIMERGY RX2520 M5 Upgrade and Maintenance Manual". Operating Manual RX2520 M5...
  • Page 31: Indicator On The Odd

    Product description HDD/SSD prefailure detection Depending on your hardware configuration HDD/SSD prefailure detection will be supported. The requirements are: – iRMC S5 Firmware 1.2 or later – supported OOB RAID system 3.3.2.3 Indicator on the ODD ODDs may have an indicator or not. Figure 12: Example: Indicator on the ODD Pos.
  • Page 32: Indicators On The Hot-Plug Hdd/Ssd Module

    Product description 3.3.2.4 Indicators on the hot-plug HDD/SSD module Figure 13: Indicators on the hot-plug HDD/SSD module Pos. Label Indicator Status Description The HDD/SSD is inactive. Access indicator green on The HDD/SSD being accessed No HDD/SSD error detected. An HDD/SSD error has been detected.
  • Page 33: Indicators On The Server Rear

    Product description 3.3.3 Indicators on the server rear 3.3.3.1 Indicators on the I/O panel ID, CSS and Global Error indicators Figure 14: Global Error, ID and CSS indicators Pos. Label Indicator Status Description The server has been highlighted using ServerView Operations indicator, blue on Manager, iRMC web interface or...
  • Page 34 An emergency flash of the iRMC firmware is in progress. For more information on the flashing blue flashing orange emergency flash of the iRMC firmware, see the "FUJITSU Server PRIMERGY RX2520 M5 Upgrade and Maintenance Manual". Operating Manual RX2520 M5...
  • Page 35 Product description LAN indicators HDD/SSD HDD/SSD HDD/SSD HDD/SSD Figure 15: LAN indicators on the I/O panel Pos. Indicator Status Description A LAN connection has been green on established. link/transfer LAN is not connected. indicator flashing LAN data transfer is in progress. green yellow on Data traffic at a transfer rate of 1 Gbit/s.
  • Page 36 Product description Indication of LAN connection supporting Energy Efficient Ethernet (EEE mode) To configure the EEE mode, it is necessary that the on board LAN or an add in LAN card supports this mode and the connected switch supports this mode as well.
  • Page 37: Indicator On Hot-Plug Psu

    Product description 3.3.3.2 Indicator on hot-plug PSU Figure 16: Indicator on hot-plug PSU Pos. Indicator Status Description flashing The server is switched off, but mains green voltage is present (standby mode). The server is switched on and operating green on properly.
  • Page 38 Product description Operating Manual RX2520 M5...
  • Page 39: Important Information

    Important information In this chapter you will find essential information regarding safety when working on your server. Depending on your server or the installed options some information is not valid for your server. CAUTION! Before installing and starting up a server, please observe the safety instructions listed in the following section.
  • Page 40 Important information Before starting up During installation and before operating the server, observe the instructions ● on environmental conditions for your server. If the server is brought in from a cold environment, condensation may form ● both inside and on the outside of the server. Wait until the server has acclimatized to room temperature and is absolutely dry before starting it up.
  • Page 41 Important information Always connect the server and the attached peripheral devices to the same ● power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage.
  • Page 42 Important information The warranty is void if the server is damaged during installation or ● replacement of server expansions. Only set screen resolutions and refresh rates that are specified in the ● operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center.
  • Page 43 Important information The battery used in this server may present a fire or chemical burn hazard if ● mistreated. Do not disassemble, heat about 100 °C (212F), or incinerate the battery. Replace the lithium battery on the system board in accordance with the ●...
  • Page 44 Important information Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray ● roughly. Do not disassemble the ODD. ● Before use, clean the ODD tray using a soft, dry cloth. ● As a precaution, remove disks from the ODD when the drive is not to ●...
  • Page 45 Important information – Protect the disks from exposure to heat and direct sunlight. Laser information The ODD complies with IEC 60825-1 laser class 1. CAUTION! The ODD contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous.
  • Page 46 Important information Do not touch any connectors or conduction paths on an ESD module. ● Place all the components on a pad which is free of electrostatic charge. ● For a detailed description of how to handle ESD modules, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).
  • Page 47: Ce Conformity

    CE conformity The system complies with the requirements of European Regulations. Find the CE declaration on certificate portal: https://sp.ts.fujitsu.com/sites/certificates/default.aspx To open the CE declaration applicable for your system, proceed as follows: Ê Select Industry Standard Servers.
  • Page 48: Energy Star

    Important information ENERGY STAR Products that have been certified compliant with ENERGY STAR and labelled are in full compliance with the specification at shipping. Note that energy consumption can be affected by software that is installed or any changes that are made to the hardware configuration or BIOS or energy options subsequently.
  • Page 49: Environmental Protection

    Consult the dealer or an experienced radio/TV technician for help. ● Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
  • Page 50 More information can be found at: http://ts.fujitsu.com/recycling Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch, or at: http://ts.fujitsu.com/recycling Operating Manual RX2520 M5...
  • Page 51: Starting Up

    Starting up CAUTION! Follow the safety instructions in chapter "Important information" on ● page Do not expose the server to extreme environmental conditions (see ● "Ambient conditions" on page 93). Protect the server from dust, humidity and heat. Ensure that the server is acclimatized for the time indicated in this ●...
  • Page 52: Installation Steps, Overview

    Starting up Installation steps, overview Ê First of all, carefully read the safety instructions in "Important information" on page 39 and following. Ê Transport the server to the place where you want to set it up. Ê Unpack the system, check the contents of the package for visible transport damage and check whether the items delivered correspond to the details on the delivery note, see "Unpacking the server"...
  • Page 53 Installation Manager" on page For more information on installing the server (remote or local), see the "ServerView Installation Manager" user guide at http://manuals.ts.fujitsu.com under x86 Servers - Software - ServerView Suite - Server Installation and Deployment. Installation without ServerView Installation Manager –...
  • Page 54: Unpacking The Server

    Ê Remove all scratching protection foils from the front panel, HDD/SSD frames, Fujitsu and PRIMERGY logo, VGA dummy and ODD dummy in case they are still sticked to the server system. Operating Manual...
  • Page 55: Installing The Server In The Rack

    If several units are simultaneously extended out of the rack, there is a risk that the rack could tip over. Fujitsu rack systems The rack systems from Fujitsu support the installation of PRIMERGY servers: – PRIMECENTER rack – PRIMECENTER M1 rack –...
  • Page 56 The power is supplied via the multiple socket outlets fitted in the rack (not valid for Japan). The main features of Fujitsu rack systems are as follows: – rail systems that can be mounted without tools – support systems having a linear alignment feature to ensure that they can...
  • Page 57: Installing The Server In The Rack

    Starting up 5.3.1 Installing the server in the rack CAUTION! At least two people are needed to position the server on the rack rails. (For Japan, see " 安全上のご注意 ".) For configurations below 32 kg: At least two people are needed to lift the server into the rack cabinet.
  • Page 58 Starting up Figure 18: Mounting the server onto the rack rails Ê Completely extend the rack rails until they lock in place (1). The rack rails must click into place so that they can no longer be moved. Ê At a slight angle, lower the server onto the rear mounting point on the rack rails (2).
  • Page 59 Starting up Figure 19: Sliding the server into the rack Ê Release the locking mechanism of both rails (1). Ê Push the server as far as it will go into the rack (2) until the quick-release levers engage (3). CAUTION! Be careful with your fingers.
  • Page 60: Connecting Cables

    Starting up Connecting cables 5.4.1 Notes on connecting/disconnecting cables CAUTION! Always read the documentation supplied with the device you wish to connect. Never connect, or disconnect cables during a thunderstorm. Never pull on a cable when disconnecting it. Always take hold of the cable by the plug.
  • Page 61: Connecting Devices To The Server

    Starting up Information for ensuring electromagnetic compatibility All data and signal cables must have sufficient shielding. The use of cable type S/FTP Cat5 or higher is recommended. Use of unshielded or badly shielded cables may lead to increased emission of interference and/or reduced fault-tolerance of the device.
  • Page 62: Connecting The Power Cord

    A second PSU can be added to ensure a redundant power supply. If one PSU is defective, the other then guarantees unimpaired operation. Each PSU can be replaced during operation (see the "PRIMERGY RX2520 M5 Server Upgrade and Maintenance Manual").
  • Page 63: Using The Cable Clamp

    Starting up 5.4.3.2 Using the cable clamp You can secure the power cord with a cable clamp to ensure that the power cord cannot be disconnected from the server by mistake. The cable clamp is included in the accessories pack that is delivered together with the server. Figure 20: Using cable clamps Ê...
  • Page 64: Switching On The Server For The First Time

    "Ambient conditions" on page 93. When operating the server out of the specified temperature range, the server may operate improperly and data loss may occur. Furthermore, Fujitsu cannot be held responsible for any related damage, malfunction, or loss of data, etc.
  • Page 65: Configuring The Server With Serverview Installation Manager

    When using the ServerView Installation Manager you can configure the onboard controller either before or during installation. Descriptions of operating systems not covered in the RAID controller manual are provided in the corresponding readme files under: http://www.fujitsu.com/global/services/computing/server/ia/driver/index. html For Japan: http://www.fujitsu.com/jp/products/computing/servers/primergy/downloa...
  • Page 66: Configuring The Controllers

    5.6.1.2 Installing the operating system For more information on installing the server, see the "ServerView Installation Manager" user guide at http://manuals.ts.fujitsu.com under x86 Servers - Software - ServerView Suite - Server Installation and Deployment. Ê Open this manual. Ê For the remote or local installation, follow the instruction in this manual and on the screen.
  • Page 67: Configuring The Server Without Serverview Installation Manager

    Starting up Configuring the server without ServerView Installation Manager 5.7.1 Configuring the server and installing the operating system 5.7.1.1 Configuring the onboard SAS/SATA controller Ê If applicable, configure the onboard SATA controller, see "Notes on configuring controllers" on page Ê If applicable, configure the SAS/SATA RAID controller with MegaRAID functionality, see "Notes on configuring controllers"...
  • Page 68: Notes On Configuring Controllers

    A separate utility is available to the controller for MegaRAID configuration. For more information, see the "SAS Software User’s Guide" (on the Fujitsu manuals server under x86 Servers - Expansion Cards - Storage Adapters - LSI Configuration Software). More information on modular RAID controllers is provided in the "Modular RAID Controller Installation Guide"...
  • Page 69: Note On Operating System

    Open the Windows operating system / Restoring the preinstalled environment For the procedure to open the Windows operation system or to restore the preinstalled environment, see the manuals on the Fujitsu manual download site (http://www.fujitsu.com/jp/products/computing/servers/primergy/manual/) or the attached manuals. Linux operating system support...
  • Page 70 Starting up Operating Manual RX2520 M5...
  • Page 71: Operation

    "Ambient conditions" on page 93. When operating the server out of the specified temperature range, the server may operate improperly and data loss may occur. Furthermore, Fujitsu cannot be held responsible for any related damage, malfunction, or loss of data, etc.
  • Page 72 Operation Switching the server on The AC connected indicator lights up green (standby mode) when the server is connected to the mains. It will take about 60 seconds until the server can be switched on. Ê Press the On/Off button. The server is switched on, performs a system test and boots the operating system.
  • Page 73 Operation – Wake up On LAN (WOL) The server is turned on by a command via the LAN (Magic Packet™). – After power failure The server automatically reboots following a power failure (depending on the settings in the BIOS or in iRMC). –...
  • Page 74: Installing Hdd/Ssd Modules

    Operation Installi ng HDD/SSD modules 6.2.1 Installing 3.5-inch HDD modules 6.2.1.1 Removing a 3.5-inch HDD dummy module Figure 21: Removing a 3.5-inch dummy module Ê Press both tabs together (1) and pull the dummy module out of its bay (2). CAUTION! Keep the dummy module for future use.
  • Page 75 Operation Figure 23: Installing the 3.5-inch HDD module Ê Insert the HDD module into a drive bay and carefully push back as far as it will go (1). Ê Close the locking lever to lock the HDD module in place (2). Ê...
  • Page 76: Installing 2.5-Inch Hdd/Ssd Modules

    Operation 6.2.2 Installing 2.5-inch HDD/SSD modules 6.2.2.1 Removing a 2.5-inch HDD/SSD dummy module Figure 24: Removing a 2.5-inch HDD/SSD dummy module Ê Press both tabs together (1) and pull the dummy module out of its bay (2). CAUTION! Keep the dummy module for future use. Always replace dummy modules into unused HDD/SSD bays to comply with applicable EMC regulations and satisfy cooling requirements.
  • Page 77 Operation Figure 26: Installing the 2.5-inch HDD/SSD module Ê Insert the HDD/SSD module into a drive bay and carefully push back as far as it will go (1). Ê Close the locking lever to lock the HDD/SSD module in place (2). Ê...
  • Page 78: Installing A Second Psu

    Operation Installing a second PSU 6.3.1 Removing the dummy cover Figure 27: Removing the PSU dummy cover Ê Press in on both release latches (1) and remove the dummy cover (2). CAUTION! Keep the dummy cover for future use. If a PSU is removed and not immediately replaced by a new one, a dummy cover must be installed in the bay again to comply with applicable EMC regulations and satisfy cooling requirements.
  • Page 79 Operation Figure 29: Installing a PSU Ê Push the PSU into its bay (1) as far as it will go until the release latch snaps in place. Ê Fold down the handle on the PSU (2). Ensure that the PSU engages correctly in the bay and is locked in position.
  • Page 80: Cleaning The Server

    Operation Cleaning the server CAUTION! Switch off the server and disconnect the power plugs from the properly grounded power outlets. Do not clean any interior parts yourself; leave this job to a service technician. Do not use any cleaning agents that contain abrasives or may corrode plastic.
  • Page 81: Troubleshooting And Tips

    Also make a list of any error messages that were displayed. Ê Switch off the server. Ê Contact our customer service team. The meaning of the error message is explained in the documentation for the relevant components and programs, available online at http://manuals.ts.fujitsu.com. Operating Manual RX2520 M5...
  • Page 82 Troubleshooting and tips Power-on indicator remains unlit after you have switched on your device Cause Troubleshooting Power cable Ê Ensure that the power cable(s) is/are correctly incorrectly connected connected to the server and the grounded power outlet(s). Power supply Ê Disconnect the server power plug(s) from the overloaded grounded power outlet(s).
  • Page 83 Troubleshooting and tips No screen display or display drifts Cause Troubleshooting Wrong horizontal Ê Find out which horizontal frequency your monitor frequency or resolution screen supports. You will find the horizontal selected frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.
  • Page 84 Ê If the date and time are still wrong after the server discharged has been switched off and back on again, replace the lithium battery (see the "FUJITSU Server PRIMERGY RX2520 M5 Upgrade and Maintenance Manual") or contact our customer service team.
  • Page 85 Ê Remove and reinstall the drive while the system is switched on. If the HDD/SSD continues to be shown as defective, then replace it (see the "FUJITSU Server PRIMERGY RX2520 M5 Server Upgrade and Maintenance Manual"). Operating Manual RX2520 M5...
  • Page 86 RAID controller configuration program. For more information, see the "Integrated RAID for SAS User’s Guide" available online http://manuals.ts.fujitsu.com under x86 Servers - Expansion Cards - Storage Adapters - LSI SAS / SCSI RAID Contollers or in the "Modular RAID Controller Installation Guide"...
  • Page 87 Troubleshooting and tips ODD cannot read data Cause Troubleshooting ODD cannot read data Ê Check to see whether the CD/DVD/BD is inserted properly. If the CD/DVD/BD is not inserted, correctly insert the disk so that the label is facing Ê Check to see whether the CD/DVD/BD is not dirty. If the CD/DVD/BD is dirty, wipe it in a radial way with a soft, dry cloth.
  • Page 88 Troubleshooting and tips Operating Manual RX2520 M5...
  • Page 89: Technical Data

    Please be forewarned. The data sheets for this server contain more technical data. The data sheets are available online at: http://www.fujitsu.com/fts/products/computing/servers/primergy For more information, see the Documents tab under e.g. Rack Servers. For Japan: http://www.fujitsu.com/jp/products/computing/servers/primergy...
  • Page 90 Technical data Interfaces USB connectors USB 3.0 connectors: 7 (2x front, 4x rear, 1x internal) USB connectors USB 2.0 connectors: 1 (1x on front panel QRL) (12 x 3.5 inch / 24 x USB 3.0 connectors: 5 (4x rear, 1x internal) 2.5 inch variant) Graphics (15-pin) 1 x VGA (rear)
  • Page 91 Technical data Onboard or integrated controllers RAID controllers PSAS CP400i with "Integrated RAID" (IR) RAID levels 0 and 1 are supported for internal HDD configurations. PRAID EP4x0 (based on LSI SAS3108) SAS/SATA HDD/SSD up to 12 Gbit/s SAS, 6 Gbit/s SATA, 8 ports internal/external RAID level: 0, 1, 1E, 10, 5, 50, 6, 60 1/2/4 GB cache, optional FBU...
  • Page 92 Technical data Slots PCI-Express - 3 x low profile Gen3 x16 PCI-Express - Gen3 x8 3 x low profile Slot notes CPU1 supports three slots PCIe Gen3 x8 and one slot PCIe Gen3 x16. One PCIe Gen3 x8 slot can be occupied with a Modular RAID controller.
  • Page 93 Technical data Dimensions / Weight Rack (W x D x H) 482.6 mm (bezel) / 444.8 mm (chassis outer dimension) / 430.8 mm (chassis) x 750 mm (outer dimension) x 86.6 mm Mounting depth rack 725.6 mm Height unit rack 19"...
  • Page 94 Technical data Noise level (depending on the configuration) The acoustic noise values are depending on the system configuration. Standard configuration Sound power level < 5.2 B (idle) (ISO 9296) < 5.3 B (operation) Sound pressure level at adjacent workstation < 34 dB (idle) (ISO 9296) <...
  • Page 95 Technical data Compliance with standards Product safety and ergonomics International IEC 60950-1 2ed; am1 + am2 Europe Safety EN 60950-1 2ed; A1 + A2 + A11 + A12 EN 62479 Ergonomics ISO 9241-3 EN 29241-3 EK1-ITB2000:20xx USA / Canada CSA-C22.2 No. 60950-1-07 2ed; am1 + am2 UL 60950-1 2ed;...
  • Page 96 Technical data CAUTION! This device meets the requirements of Class A CISPR 22/32. This device can cause radio interference in residential areas. Operating Manual RX2520 M5...
  • Page 97: Warranty And Service

    Warranty and service Warranty The warranty regulations can be found online at:http://manuals.ts.fujitsu.com under x86 Servers - Safety / Eco / Warranty For Japan: http://www.fujitsu.com/jp/products/computing/servers/primergy/support/ For the warranty regulations select " 製品保証ご案内 ( 無償修理期間 )" Service Telephone numbers of the local service partner can be found online at: http://ts.fujitsu.com/support/servicedesk.html...
  • Page 98 Warranty and service Operating Manual RX2520 M5...