Quick Start Guide Section 1 GFK-2893P Sep 2019 1. Physical Characteristics The following diagrams illustrate the physical layout of the Quick Panel Operator Interface, including locations of status LEDs, communications ports, and connectors. Figure 1.1: IC755CxS06RDx Profile and Hardware Features Note: Refer to the table IC755CxW06CDx Specifications...
Page 4
Quick Start Guide Section 1 GFK-2893P Sep 2019 Figure 1.2: IC755CxW07CDx Profile and Hardware Features Note: Refer to the table IC755CxW07CDx Specifications for drawing dimensions. Physical Characteristics...
Page 5
Quick Start Guide Section 1 GFK-2893P Sep 2019 Figure 1.3: IC755CxS10CDx Profile and Hardware Features Note: Refer to the table IC755CxS10CDx Specifications for drawing dimensions Physical Characteristics...
Page 6
Quick Start Guide Section 1 GFK-2893P Sep 2019 Figure 1.4: IC755CxS12CDx Profile and Hardware Features Note: Refer to the table IC755CxS12CDx Specifications for drawing dimensions. Physical Characteristics...
Page 7
Quick Start Guide Section 1 GFK-2893P Sep 2019 Figure 1.5: IC755CxS15CDx Profile and Hardware Features Note: Refer to the table IC755CxS15CDx Specifications for drawing dimensions. Physical Characteristics...
Quick Start Guide Section 2 GFK-2893P Sep 2019 2.2 Environmental Specifications Note: Install the Quick Panel in a well-ventilated location that is not exposed to dust, corrosive gases or liquids, rain, strong ultra-violet light or direct sunlight, and meets the following specifications.
Quick Start Guide Section 3 GFK-2893P Sep 2019 3. Initial Startup Note: For installation requirements, complete installation procedures, and operating information, refer to the QuickPanel+ Operator Interface User Manual (GFK- 2847). You will need the following: A Safety Extra Low Voltage (SELV) and Limited ▪...
Page 15
Quick Start Guide Section 3 GFK-2893P Sep 2019 3.1 Quick Panel+ Battery Installation CAUTION • Installing the battery should only be performed by trained personnel and in a non-hazardous location. • If the QuickPanel is VESA mounted, detach from the VESA arm when replacing the battery. Refer to the section, Mounting on a VESA arm.
Page 16
Quick Start Guide Section 3 GFK-2893P Sep 2019 Connect the battery harness connector to the header, noting keyed orientation. Figure 3.2: IC755CxS06RDx /IC755CxW07CDx Battery Harness Connection Battery Part Number IC755ACCBATT Verify that positive (red) is down and negative (black) is up. Wrap the harness connector around to match the following figure.
Use of batteries not specified for use with the Quick Panel+ product may present a risk of fire or explosion. Caution • Replace the battery for the IC755CxS06RDx only with Emerson battery part number IC755ACCBATT. • Replace the battery for the IC755CxW07CDx only...
Quick Start Guide Section 3 GFK-2893P Sep 2019 Secure the power cable to the mating connector, noting polarity, and tighten the screw clamps. The torque for the attaching screws is 0.3 Nm (2.26 in-lb). Apply dc power to the unit. During normal startup and operation, the Quick Panel status LED indicator displays as follows:...
Page 19
Quick Start Guide Section 3 GFK-2893P Sep 2019 3.4.2 Ethernet Port Operation LEDs The Ethernet port has two LED indicators: Speed and Link Activity. Operating LED State State Speed Link Activity Speed Yellow, on 10/100 Link Green, on Link status Activity Initial Startup...
Quick Start Guide Section 4 GFK-2893P Sep 2019 4. Mounting and Installation 4.1 Protective Sheet Installation ➢ To install the protective sheet Remove protective film from QuickPanel display screen. Wipe the display unit of any dust or fingerprints. Peel back a corner of the clear side of the protective sheet.
Quick Start Guide Section 4 GFK-2893P Sep 2019 Figure 4.1: Mounting Angle 4.3 Panel Mounting To mount the Quick Panel in an enclosure, you will need the following equipment: • One #2 Phillips head screwdriver • Mounting brackets (supplied) mounting holes IC755CxS06RDx, IC755CxW07CDx, and IC755CxS10CDx are located on...
Page 22
Quick Start Guide Section 4 GFK-2893P Sep 2019 Figure 4.3: IC755CxW07CDx Mounting Holes Figure 4.4: IC755CxS10CDx Mounting Holes The IC755CxS12CDx and IC755CxS15CDx mounting holes are located on the top, bottom, and sides of the unit. Mounting & Installation...
Page 23
Quick Start Guide Section 4 GFK-2893P Sep 2019 Figure 4.5: IC755CxS12CDx Mounting Holes Figure 4.6: IC755CxS15CDx Mounting Holes 4.4 Mounting and Installation Procedure CAUTION • When installing the Quick Panel into the panel, pay careful attention while handling the unit so it does not drop and damage the unit.
Page 24
Quick Start Guide Section 4 GFK-2893P Sep 2019 Note: Panel cutout tolerances are +0.50, -0.00 mm (+0.02, - 0.00 in). Figure 4.7: IC755CxS06RDx Panel Cutout Dimensions 183.50 mm (7.22 in) Panel Thickness: 1.0 to 5.0 mm (0.04 to 0.20 in) Figure 4.8: IC755CxW07CDx Panel Cutout Dimensions Figure 4.9: IC755CxS10CDx Panel Cutout Dimensions 266 mm (10.47 in)
Page 25
Quick Start Guide Section 4 GFK-2893P Sep 2019 Figure 4.10: IC755CxS12CDx Panel Cutout Dimensions 302 mm (11.89 in) Panel Thickness: 1.6 to 5.0 mm (0.06 to 0.20 in) Figure 4.11: IC755CxS15CDx Panel Cutout Dimensions Verify that the gasket is present and properly seated in the bezel channel located on the sides of the unit.
Page 26
Quick Start Guide Section 4 GFK-2893P Sep 2019 Insert the hook of the mounting bracket into the mounting hole as displayed in the following figure. Figure 4.13: Hook of Mounting Bracket Tighten the screws on the mounting bracket in a clock-wise direction. Figure 4.14: Mounting bracket screw turning Torque Range for Mounting Clamp Screws Display Unit...
Quick Start Guide Section 4 GFK-2893P Sep 2019 4.5 VESA Arm Mounting The Quick Panel can be installed on a commercially available Video Electronics Standards Association (VESA) MIS-D arm, stand, or apparatus that complies with the UL1678 standard. ➢ To VESA mount the Quick Panel unit: use the mounting holes located on the back of the unit (displayed in the following figures).
Page 28
Sep 2019 Figure 4.15: IC755CxW07CDx/IC755CxS06RDx VESA Mounting Holes Figure 4.16: IC755CxSxxCDx VESA Mounting Holes 100 mm (3.94 in) Note: For user manuals, product updates, and other information, Support website, https://www.emerson.com/Industrial-Automation- Controls/support and refer to Operator Interfaces and Mounting & Installation...
Quick Start Guide Section 4 GFK-2893P Sep 2019 4.6 Connectors 4.6.1 Power Connector Details Pin # Signal Name Pin-out +24 V dc † † IC755CxSxxCDA supports both +12 V dc or +24 V dc IN 4.6.2 Ethernet Port Details Interface: Ethernet 10BASE-T/100BASE-TX Pin # Signal Name Pin-out...
Quick Start Guide Section 4 GFK-2893P Sep 2019 4.6.4 Serial Port Details 4.6.4.1 IC755CxS06RDx 4.6.4.1.1 Serial Port COM1 Interface: RS-232 Pin # Signal Name SGND Figure 4.2: IC755CxS06RDx Serial Port COM1 Pin-out IC755CxW07CDx Interface: x1 RS-232 Pin# Signal Name SGND Mounting &...
Page 31
Quick Start Guide Section 4 GFK-2893P Sep 2019 Figure 4.3: IC755CxW07CDx Serial Port COM1 Pin-out Pin 1 Pin 5 4.6.4.3 IC755CxSxxCDx 4.6.4.3.1 Serial Port COM1 Interface: RS-232 Pin # Signal Name SGND Figure 4.4: C755CxSxxCDx Serial Port COM1 Pin-out Mounting & Installation...
Page 32
Quick Start Guide Section 4 GFK-2893P Sep 2019 4.6.4.3.2 Serial Port COM2 Interface: RS-232C/485 (default is RS-485 Half-duplex) RS-232 RS-485 Signal Name Signal Name Pin # Signal (Full- (Half- Name duplex † duplex † ‡ TXD+ DATA+ TXD- DATA- ‡ ‡...
Quick Start Guide Section 5 GFK-2893P Aug 2019 5. Product Certifications and Installation Guidelines for Conformance The Quick Panel Operator Interface is intended for use in industrial environments and, when properly installed, shall comply with the following agency approvals. 5.1 Agency Approvals Note: The agency approvals listed in the following table and on the Declaration of Conformities are believed to be accurate.
Page 34
Quick Start Guide Section 5 GFK-2893P Sep 2019 Agency Description Comments Marking Certification in accordance with the ATEX Directive 14/34/EU with an Explosive Independent 3rd Atmospheres Party Assessment Directive Certificate only European Safety applies to the 12” and for Hazardous 15”...
Page 35
Quick Start Guide Section 5 GFK-2893P Sep 2019 Agency Description Comments Marking 7, 10, 12, 15” units only. 5.2 Conditions of Safe Use for Installation in Hazardous Locations The following information applies to products bearing the UL marking for Hazardous areas and the ATEX marking for Zone 2 explosive atmospheres: •...
Page 36
Quick Start Guide Section 5 GFK-2893P Sep 2019 Transient protection shall be provided that is set at a level not exceeding 140% of the peak rated voltage value at the supply terminals to the equipment. • USB retaining clamp for IC755CxS12CDBCA and IC755CxS15CDACA must be used in hazardous location installations as follows: Connect the USB cable.
Page 37
Quick Start Guide Section 5 GFK-2893P Sep 2019 clamp. Then close the retaining clamp to fit the cable size. Figure 5.3: Adjusting position of retaining clamp • USB retaining clamp for IC755CSW07CDACA must used hazardous location installations as follows: Connect the USB retaining clamp plate. Figure 5.4: USB retaining Clamp Plate Connect the USB cable and insert the retaining clamp into the retaining clamp...
Page 38
Quick Start Guide Section 5 GFK-2893P Sep 2019 Figure 5.5: USB cable retaining clamp Adjust the position of the retaining clamp by pushing the lever of the retaining clamp. Then close the retaining clamp to fit the cable size. Figure 5.6: Inserting retaining clamp Product Certification &...
Changes or modifications to this unit that are not expressly approved by Emerson could void the user’s authority to operate the equipment. Product Certification & Installation Guidelines...
Page 40
Quick Start Guide Section 5 GFK-2893P Sep 2019 Industry Canada requires the following note to be published: Note: This Class A digital apparatus complies with Canadian CAN ICES-3 (A)/NMB-3 (A). 5.4 EMC Installation and Operation Considerations This equipment is intended for industrial use only and complies with a minimum level of EMC performance as defined by EN 61000-6-2 and EN 61000-6-4 standards.
Page 42
Note: If the product is purchased through an Authorized Channel Partner, please contact the seller directly for any support. Emerson reserves the right to modify or improve the designs or specifications of the products mentioned in this manual at any time without notice. Emerson does not assume responsibility for the selection, use or maintenance of any product.