Comfort. In case of underfloor heating, the wireless external room thermostat
prevents condensation on the floor during cooling operation by measuring the
room humidity.
Setup
A
Main leaving water temperature zone
B
One single room
a
Remote controller of the heat pump convectors
For more information about connecting the electrical wiring to the unit, see:
-
"8.2 Connections to the outdoor
-
"8.3 Connections to the indoor
The heat pump convectors are directly connected to the indoor unit.
The desired room temperature is set via the controller of the heat pump
convectors. There are different controllers and setups possible for the heat pump
convectors. For more information, see:
-
The installation manual of the heat pump convectors
-
The installation manual of the heat pump convector options
-
The addendum book for optional equipment
The space heating/cooling demand signal is sent to one digital input on the
indoor unit (X2M/35 and X2M/30).
The space operation mode is sent to the heat  pump convectors by one digital
output on the indoor unit (X2M/4 and X2M/3).
Configuration
Setting
Unit temperature control:
#: [A.2.1.7]
Code: [C-07]
External room thermostat for the main
zone:
#: [A.2.2.4]
Code: [C-05]
Benefits
Cooling. The heat pump convector offers, besides heating capacity, also excellent
cooling capacity.
Efficiency. Optimal energy efficiency because of the interlink function.
5
Application guidelines
|
A
B
a
4
unit" [
 90]
4
unit" [
 91]
1 (Ext RT control): Unit operation
is decided by the external thermostat.
1 (Thermo ON/OFF): When the used
external room thermostat or heat pump
convector can only send a thermo ON/
OFF condition.