Registry Key
CompositeCodeMarkCC-AB
CompositeCodeMarkCC-C
UPCAndEANCompositeMessageDecoding
CompositeABUDSI
CompositeCUDSI
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Multicode] - Multiple Symbology Concatenation Support
MulticodeActivation
MulticodeNumberOfBarcodes
MulticodeIncompleteTransmission
MulticodeCodeMark
MulticodeCodeMarkOfIncomplete
MulticodeIDForBarcode1
MulticodeIDForBarcode2
MulticodeIDForBarcode3
MulticodeIDForBarcode4
MulticodeIDForBarcode5
MulticodeIDForBarcode6
MulticodeIDForBarcode7
MulticodeIDForBarcode8
Default Value
Description
0x2a
A single character inserted before the barcode data to
indicate the symbology.
0x2a
A single character inserted before the barcode data to
indicate the symbology.
0x2
Decode mode for EAN/UPC composites, where 0 = never
linked (only EAN/UPC transmitted), 1 = always linked (2D
component required), and 2 = autodiscriminate.
"G0"
User-defined symbology identifier. Range is 0-4 characters.
TODO
User-defined symbology identifier. Range is 0-4 characters.
0x0
Activates the ability to read multiple barcodes with
one trigger press. If this value is set to 1 (enabled),
then barcodes that don't match the masking criteria can
be returned independently of other barcodes (normal
operation). If this value is set to 2 (exclusive), then
barcodes that don't match the masking criteria will be
discarded.
0x2
Number of barcodes in the multicode. Range is 2-8.
0x0
Enables transmission of incomplete multicode after the
timeout is reached.
0x2a
A single character inserted before the barcode data to
indicate the symbology.
0x2a
A single character inserted before the barcode data
to indicate the symbology. Used when incomplete
transmission is enabled and the timeout is reached.
0x0
Intermec-specific symbology identifier (0x0 is disabled).
See manufacturer's website for details.
0x0
Intermec-specific symbology identifier (0x0 is disabled).
See manufacturer's website for details.
0x0
Intermec-specific symbology identifier (0x0 is disabled).
See manufacturer's website for details.
0x0
Intermec-specific symbology identifier (0x0 is disabled).
See manufacturer's website for details.
0x0
Intermec-specific symbology identifier (0x0 is disabled).
See manufacturer's website for details.
0x0
Intermec-specific symbology identifier (0x0 is disabled).
See manufacturer's website for details.
0x0
Intermec-specific symbology identifier (0x0 is disabled).
See manufacturer's website for details.
0x0
Intermec-specific symbology identifier (0x0 is disabled).
See manufacturer's website for details.