Easy Configuration: Bringing Additional T5, T5M, And A500 Devices Online; Talkman T5 Vmt - Honeywell Vocollect Hardware Reference Manual

Table of Contents
1. Create a device profile in VoiceConsole.
You can set the device profile as a "default profile," which automatically loads to any bare-platform devices. The
devices must be in standby mode and connected to VoiceConsole.
Note: The Talkman A500 model TT-802 ships as a bare-platform device. It does not have Vocollect voice
software—VoiceCatalyst or VoiceClient—preloaded.
2. In the Advanced Device Settings text box, type this parameter: "distributable"="1"
The value of "1" marks the device profile as one that can be shared with other devices using the serial connection
between bays in the T5/A500 charger. If this parameter is not placed in the device profile or if its value is set to
zero, the device profile will not be shared.
3. Follow the instructions in the VoiceConsole online help for completing the device profile.
4. Use a serial cable to load this profile to a single device.
Note: If the device profile you are loading is configured for use with static IP addresses, all the devices
will have the same IP address.

Easy Configuration: Bringing Additional T5, T5m, and A500 Devices Online

A single device has been configured using the Easy Configuration Initial Setup instructions and VoiceConsole Online
Help. The following instructions are for configuring additional devices.
1. Place a properly configured T5, T5m, or A500 device in the transmit bay in the charger. When facing the charger
bay, the transmit bay is the first bay on the right. It is identified with an off-white latch. The other bays have dark
gray latches.
2. Place the new or repaired T5, T5m, or A500 devices in the remaining charger bays.
The LED indicators on the unconfigured devices flash green until the devices determine that they cannot reach
VoiceConsole.
The LED indicators flash orange as the devices attempt to connect to the network to listen for a file broadcast.
The LED indicators flash green briefly as the devices receive profiles from the configured device and verify
the configuration.
The LED indicators change to solid red as the devices reboot.
When the devices have applied the configuration file and successfully contacted VoiceConsole, the LED
indicators change to blinking green. The devices are then ready to use or can be used in another charger to
bring additional devices online.
Note: The AC power indicator at the bottom right of the charger displays alternating green and yellow
lights when Easy Configuration operations are occurring. Devices should not be removed until the
individual indicator on the device blinks green or the charger's power indicator glows solid green.

Talkman T5 VMT

A Talkman T5 VMT is a T5-Series device with a battery adapter mounted to a vehicle, such as a forklift or motorized
pallet jack. After the device is mounted, the battery adapter is placed in the battery area of the T5-Series device and
connected to the vehicle's power source.
Talkman devices in this configuration may use any wired or wireless equipment (headsets, scanners, etc.). Honeywell
sells the complete solution including mounting kits and power systems to enable any Talkman T5-Series devices to be
used in a T5 VMT configuration.
CAUTION: PLEASE DO NOT LOOK AT DEVICE/UNIT WHILE OPERATING MACHINERY SO
AS TO AVOID CREATION OF A DISTRACTION THAT COULD RESULT IN AN ACCIDENT AND
BODILY INJURY TO OPERATOR AND THIRD PERSONS.
Follow the instructions below to properly install the device in a forklift.
Determine the best location for mounting the device, taking into consideration the driver's field of view.
Install the appropriate mounting hardware.