Installing system components
3.8 Selecting the connection box
Connection box standard and connection box advanced
1. Switch off power supply to the connection box.
2. Open the connection box.
3. Disconnect the following cables from the connection box:
– All cables at the port X10
– The Ethernet cables at Fast Connector X1 and Fast Connector X2
4. Thread all connecting cables through the associated cable glands out of the connection
box.
5. Close the connection box.
6. Close off all cable glands with a cover.
7. Remove the four outermost screws used to fasten the connection box.
8. Remove the connection box from its mounting location.
See also
Connecting the KTP Mobile connecting cable to the connection box (Page 73)
Connecting the connection box (Page 59)
Installing system components (Page 43)
76
Mobile Panels 2nd Generation
Operating Instructions, 09/2018, A5E33876626-AC