Configuring the Mobile Panel
6.1 Configuration in WinCC
3. Select an HMI device of the type KTP Mobile or KTP F Mobile for an F-system and select
the "Start Device Wizard" checkbox.
4. Select "Finish".
The Mobile Panel is added to the project.
6.1.3

Configuring a fail-safe Mobile Panel

The emergency stop or stop can be evaluated either by a hardwired F-system or by a
PROFIsafe-based F-system.
● For a hardwired F-system:
The fail-safe Mobile Panel must be configured like a non-fail-safe Mobile Panel. The
"PROFIsafe" option must not be activated.
● PROFIsafe-based F-system:
The "PROFIsafe" option must be enabled for the fail-safe Mobile Panel.
The following procedure is for configuring a fail-safe Mobile Panel.