COMMAND CODE TITLE:
D102
FUNCTION:
This command is used to clear the memory for billing and to load the assigned data for call record when
using PN-AP00-B with AP00 program.
PRECAUTION:
(1)
After billing system data all clear is executed by CMD101, assign the system data in the following
order.
STEP 1: Make the AP00 card OFF LINE by switch setting as shown below.
SW1
ON
STEP 2: CMD001>179
STEP 3: CMD003>23, 24, 25, 26, 28, 29, 30
STEP 4: CMD102>0000: CCC
STEP 5: Make the AP00 card ON LINE by switch setting as shown below.
SW1
ON
STEP 6: Flip the MB switch on the AP00 card to ON (UP position), then OFF (DOWN position).
BILLING MEMORY CLEAR FOR PN-AP00-B WITH
AP00 PROGRAM
4
3
: Position to be set
2
1
4
3
: Position to be set
2
1
SW1-4 should be set as follows;
ON : The AP No. is 04-15
OFF: The AP No. is 20-31
SW1-4 should be set as follows;
ON : The AP No. is 04-15
OFF: The AP No. is 20-31