NEC Univerge NEAX 2000 IPS Command Manual page 753

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents
COMMAND CODE TITLE:
EA
Y
No.
MEANING
2
Fault information
store into memory,
and control of
external alarm
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
1ST DATA
DATA
MEANING
Fault Kind: Restoration
18
FP/AP card returned to normal
condition
19
Power failure returned to nor-
mal condition
30
DTI line returned to normal
condition
31
DCH/BRT/PRT D-channel link
connection returned to normal
condition
32
CCH link connection returned
to normal condition
CCH/IPT link connection
returned to normal condition
[Series 3300 software
required]
34
Number of faulty trunks was
less than predetermined number
[Australia Only]
35
Number of lockout stations
restored to less than predeter-
mined number
36
DLC card returned to normal
condition
38
SMDR output buffer memory
returned to normal condition
3B
CS/ZT returned to normal con-
dition
3C
LAN application returned to
normal condition
[Series 3400]
2ND DATA
DATA
0
External Alarm Kind
0: Fault Memory
3
1: Fault Memory
2: Fault Memory
3: Fault Memory
NOTE 8
NONE
No Fault Memory
store/No External
NOTE 9
Alarm output
To assign NONE,
enter CCC.
NOTE 10
NOTE 5
– 729 –
: Initial Data
RELATED
COMMAND
MEANING
CM08>450, 451
store/No output of
CM42>01, 50
External Alarm
store/External
Alarm is MN
alarm
store/External
Alarm is MJ
alarm
store/External
Alarm Kind is
determined by
standard data
[See 2: External
Alarm Kind (MJ/
MN/– –)]
Page 739
Continued on next page
NWA-008844-001 Rev.5.0
CMEA
91ch3008.fm
JUNE/01/2007
Table of Contents
loading