[Cmd027] Call Charge Development Tables - NEC Univerge NEAX 2000 IPS Command Manual

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents
COMMAND CODE TITLE:
D027
FUNCTION:
This command is used to assign the charging method to each dialed digit on the basis of each Develop-
ment Table designated by CMD026.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
ST
+
D027
+ DE
DATA TABLE:
XXX Y
XXX: Development Table No. (000-511)
Y
: Dialed digit (0-9, A(*), B(#))
NOTE:
The actual digits sent from a trunk should be assigned.
VARIOUS DATA
DATA
0-511
Table No. for Next Development Table
X YY ZZ
X : K-Method/H-Method=0/1
YY: Kind of charging (00-15)
ZZ : Charging Rank (00-15)
0-9
Charging No. of Flat Rate assigned by
CMD004
10000
NOTE:
Charging will start when the number is dialed.
CALL CHARGE DEVELOPMENT TABLES
1ST DATA
+
+
DE
(4 digits)
1ST DATA
MEANING
2ND DATA
+
+
EXE
(1-6 digits)
NOTE
DATA
1
No charge
2
Charging is not available
3
Wait for next digit
4
Charging Identification No.
6
With answer signal
A
No answer signal
9
Send to SMDR terminal
8
Charging by metering pulse
– 846 –
2ND DATA
XXXXX Y
XXXXX: Various Data
Y
: Attribute Data
Refer to the following table
ATTRIBUTE DATA
MEANING
NWA-008844-001 Rev.5.0
CMD027
: Initial Data
: Initial Data
NOTE
91ch3009.fm
Table of Contents
loading

Table of Contents