Allen-Bradley PowerFlex 755 User Manual page 257

Integrated safety functions option module
Hide thumbs Also See for PowerFlex 755:
Table of Contents
Table 20 - Device Config Parameters (continued)
No.
Display Name
Full Name
Description
22
Enc1 Accel
Primary encoder
acceleration in units/
s2. The units of this
value are of the type
reported by parameter
24 - (En1 Unit).
23
Enc1 Fault Type
The fault type being
reported by the
primary encoder.
24
Enc1 Unit
Primary encoder
feedback units (set by
safety configuration).
30
Enc2 Position
The position count
being reported by the
secondary encoder.
Rockwell Automation Publication 750-UM005A-EN-P - October 2018
Values
Description
"No Fault" (1)
No fault reported by the primary
encoder.
"Config" (2)
The encoder's configuration is invalid.
"Max Speed" (3)
The encoder speed has exceeded the
configured maximum speed.
"Max Accel" (4)
The encoder acceleration has exceeded
the configured maximum acceleration.
"Sin2+Cos2" (5)
The encoder has failed the vector length
or aspect ratio checks.
"Quadrature" (6)
The encoder has exceeded the maximum
number of quadrature signal errors.
"Discrepancy" (7)
The associated dual channel feedback
instance has reported a discrepancy.
"Partner" (8)
The associated dual channel feedback
instance has detected a fault in the other
encoder.
"Voltage" (9)
The encoder voltage supply has gone out
of the configured range.
"SignalNoise" (10)
The encoder signals have noise that is
preventing operation.
"Signal Lost" (11)
The encoder signals are not present.
"Data Lost" (12)
Stopped receiving data from a Digital
Encoder.
"Device Fail" (13)
The encoder device has failed.
"Max Freq" (107)
The frequency of the encoder has
exceeded the maximum level for this
product.
"SinCosOffset" (108)
The offset of the Sine/Cosine signal from
ground is outside the required level.
"Pos Rollover" (109)
The encoder position count has exceeded
the maximum value that can be
represented in this product.
"Revolution" (0)
Encoder units are represented in terms of
revolutions.
"Meter" (1)
Encoder units are represented in terms of
meters.
Parameter Data
Appendix D
Data Type
REAL
BYTE
BYTE
DWORD
257
Table of Contents
loading