ABB ACS 601 Hardware Manual page 35

Ac drives, 3 to 150 hp, 2.2 to 110 kw
Hide thumbs Also See for ACS 601:
Table of Contents
Figure 3-6 Replacing the front cover
Control Panel in
Remote Use
ACS/ACC/ACP 601 Drives
Frames R2 to R3
Connect the Control Panel cable to the connector X2,
and replace the front cover.
Frames R4 to R6
1. Replace the front cover.
2. Replace the telephone connector.
3. Attach the Control Panel by pushing it softly down onto the
connector in the front cover hollow.
Connect the Control Panel cable to terminal X19 of the NAMC-11, or
with NAMC-03 board to terminal X28 of the NIOC board (X300 of the
NIOCP board).
ACx 601/604 with NAMC-3 board and ACx 607
NIOC
X28
X300
NIOCP board
Chapter 3 – Electrical Installation
Frame R7
ACx 601/604 with NAMC-11 board
Ground the cable
screen at the near
Grounding screw.
ACx=ACS/ACC/ACP
NAMC-11 with NDCO
X19
NAMC-11