Programming Procedure; Fault Message - NEC UNIVERGE SV8300 System Maintenance Manual

Ip pbx
Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Programming Procedure

Fault Message

(1)
To set the fault information storage from the PCPro by Command Operation
START
CM08
Enable the fault information storage feature.
CMEA
Assign which kind of fault information is
stored into the fault information memory, and
which kind of alarm is indicated.
NOTE:
DATA
Fault Kind: Occurrence
001
012
016
017
021
022
025
026
028
029
02B
02C
A
DESCRIPTION
CMEA programming can be set by the PCPro.
1ST DATA
MEANING
System reset
CS/ZT fault occurred
It is a day periodic maintenance
Activation Code error occurred during the
License Activation (Center Activation)
ISDN D-channel link connection failure
CCIS link connection failure
Number of lockout stations was more than
predetermined number
DLC blade down
SMDR output buffer (SRAM) exceeded 80
%
[8300R3 software required]
SMDR output buffer (SRAM) overflow
[8300R3 software required]
CS/ZT fault occurred
LAN application fault occurred
Chapter 1 MAINTENANCE SERVICES
(1)
450
(2)
1 : To store
Y=2
(1)
See the following table.
(2)
See the following table.
DATA
0
External Alarm Kind
0: Fault Memory store/No output of
NOTE 1
3
External Alarm
1: Fault Memory store/External Alarm is
MN alarm
2: Fault Memory store/External Alarm is
MJ alarm
3: No Fault Memory store/No External
Alarm output
NOTE 2
NOTE 3
1-6
FAULT MESSAGE
DATA
2ND DATA
MEANING
Continued on next page
NWA-033627-001 Rev.4.0
95ch1001.fm
JULY/17/2009