Example For Configuring Ethernet Cfm - Huawei NetEngine80E Configuration Manual - Reliability

Hide thumbs Also See for NetEngine80E:
Table of Contents
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
l

8.18.3 Example for Configuring Ethernet CFM

In this example, by configuring basic Ethernet CFM, you can implement end-to-end connectivity
fault detection.
Networking Requirements
The Ethernet shown in
B, and Router D. ISP 2 manages Router C, Router E, Router F, Router G, Router H, and Router
I. It is required that connectivity detection be implemented on the network.
Figure 8-18 Diagram of configuring Ethernet CFM
Issue 02 (2011-09-10)
efm enable
#
return
Configuration file of Router B
#
sysname RouterB
#
efm enable
#
interface GigabitEthernet2/0/1
efm enable
#
return
Figure 8-18
VLAN2
GE1/0/0
RouterI
GE1/0/2
GE1/0/1
GE1/0/0
GE1/0/2
VLAN2
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
is managed by two ISPs. ISP 1 manages Router A, Router
RouterA
GE1/0/1
RouterB
MD2
GE1/0/0
RouterD
RouterH
MD1
GE1/0/1
VLAN3
MD1
MEP of MA1
MEP of MA2
8 Ethernet OAM Configuration
VLAN2
GE1/0/1
RouterE
GE1/0/0
RouterF
GE1/0/1
GE1/0/2
RouterC
RouterG
GE1/0/0
VLAN3
MD2
MEP of MA3
463