This is a quick reference to all parameters in the drive showing units,
ranges limits etc, with block diagrams to illustrate their function. Full
descriptions of the parameters can be found in the Advanced User
Guide on the supplied CD ROM.
These advanced parameters are listed for reference
purposes only. The lists in this chapter do not include
sufficient information for adjusting these parameters.
Incorrect adjustment can affect the safety of the system, and
WARNING
damage the drive and or external equipment. Before
attempting to adjust any of these parameters, refer to the
Advanced User Guide.

Table 11-1 Menu descriptions

Menu
number
Commonly used basic set up parameters for quick / easy
0
programming
1
Frequency / speed reference
2
Ramps
3
Frequency slaving, speed feedback and speed control
4
Torque and current control
5
Motor control
6
Sequencer and clock
7
Analog I/O
8
Digital I/O
9
Programmable logic, motorized pot and binary sum
10
Status and trips
11
General drive set-up
12
Threshold detectors and variable selectors
13
Position control
14
User PID controller
18
Application menu 1
19
Application menu 2
20
Application menu 3
21
Second motor parameters
22
Additional Menu 0 set-up
Operation mode abbreviations:
OL>
Open loop
CL>
Closed loop (which incorporates closed loop vector and
servo mode)
VT>
Closed loop vector mode
SV>
Servo
Default abbreviations:
EUR> European default value (50Hz AC supply frequency)
USA> USA default value (60Hz AC supply frequency)
NOTE
Parameter numbers shown in brackets {...} are the equivalent Menu 0
parameters. Some Menu 0 parameters appear twice since their function
depends on the operating mode.
The Range - CL column applies to both Closed-loop Vector and Closed-
loop Servo. For some parameters, this column applies only to one of
these modes; this is indicated accordingly in the Default columns.
In some cases, the function or range of a parameter is affected by the
setting of another parameter; the information in the lists relates to the
default condition of such parameters.
128
Electrical
Getting
Basic
Running the
Installation
Started
parameters
Description
www.controltechniques.com
SMARTCARD
Optimization
motor
operation

Table 11-2 Key to parameter table coding

Coding
RW
Read/write: can be written by the user
RO
Read only: can only be read by the user
Bit
1 bit parameter. 'On' or 'OFF' on the display
Bi
Bipolar parameter
Uni
Unipolar parameter
Txt
Text: the parameter uses text strings instead of numbers.
Filtered: some parameters which can have rapidly changing
FI
values are filtered when displayed on the drive keypad for
easy viewing.
Destination: This parameter selects the destination of an
DE
input or logic function.
Rating dependent: this parameter is likely to have different
values and ranges with drives of different voltage and
current ratings. Parameters with this attribute will not be
transferred to the destination drive by SMARTCARDs when
RA
the rating of the destination drive is different from the
source drive and the file is a parameter file. However, with
software V01.09.00 and later the value will be transferred if
only the current rating is different and the file is a
differences from default type file.
Not copied: not transferred to or from SMARTCARDs
NC
during copying.
PT
Protected: cannot be used as a destination.
User save: parameter saved in drive EEPROM when the
US
user initiates a parameter save.
Power-down save: parameter automatically saved in drive
EEPROM when the under volts (UV) trip occurs. With
PS
software version V01.08.00 and later, power-down save
parameters are also saved in the drive when the user
initiates a parameter save.
Technical
Onboard
Advanced
Diagnostics
PLC
parameters
Data
Attribute
Unidrive SP Free Standing User Guide
Issue Number: 1
UL Listing
Information
Table of Contents
loading

Table of Contents