Forced Operation Mode; Standby Electricity Saving - Daikin FTXS20G2V1B Service Manual

G-series
Hide thumbs Also See for FTXS20G2V1B:
Table of Contents
SiENBE04-808_A

3.13 Forced Operation Mode

Outline
Forced operation mode includes only forced cooling.
Detail
Conditions
Start
Command
frequency
End
Others

3.14 Standby Electricity Saving

20-42 Class Only
This function turns power supply OFF to the outdoor unit and sets the indoor unit into energy-
saving mode, thus reducing the power consumption of the air conditioner.
For 20/25/35 class models, field setting is required for turning ON the function.
Refer to "Standby Electricity Saving" on page 290 for detail.
Function and Control
Item
1) The outdoor unit is not abnormal and not in the 3-minute standby mode.
2) The outdoor unit is not operating.
The forced operation is allowed when the above both conditions are met.
1) Press the forced operation ON/OFF button (SW1) on the indoor unit for 5
seconds.
2) Press the forced operation ON/OFF button (SW1) on the outdoor unit.
RK(X)S20-35G2V1B, ARXS20-35G2V1B: 68 Hz
RK(X)S20-35G2V1B9, ARXS20-35G3V1B: 58 Hz
RK(X)S42G2V1B, ARXS42G2V1B: 47 Hz
RK(X)S50G2V1B, ARXS50G2V1B: 66 Hz
1) The operation ends automatically after 15 minutes.
2) Press the forced operation ON/OFF button (SW1) on the indoor unit again.
3) Press the ON/OFF button on the remote control.
4) Press the forced operation ON/OFF button (SW1) on the outdoor unit.
The protection functions are prior to all others in the forced operation.
Control Specification
Forced Cooling
60

Hide quick links:

Table of Contents
loading