Daikin ATXS20G2V1B Operation Manual

Daikin ATXS20G2V1B Operation Manual

Daikin room air conditioner siesta
Hide thumbs Also See for ATXS20G2V1B:
DAIKIN ROOM AIR CONDITIONER

Operation Manual

MODELS
ATXS20G2V1B
ATXS25G2V1B
ATXS35G2V1B
ATXS42G2V1B
ATXS50G2V1B
English
Deutsch
Français
Nederlands
Español
Italiano
ΕλληνικÜ
Portugues
Table of Contents
loading

Summary of Contents for Daikin ATXS20G2V1B

  • Page 1: Operation Manual

    DAIKIN ROOM AIR CONDITIONER MODELS ATXS20G2V1B ATXS25G2V1B Operation Manual ATXS35G2V1B ATXS42G2V1B ATXS50G2V1B English Deutsch Français Nederlands Español Italiano ΕλληνικÜ Portugues...
  • Page 2: Table Of Contents

    CONTENTS READ BEFORE OPERATION Safety precautions ......... 2 Names of parts..........4 Preparation Before Operation ......7 OPERATION AUTO · DRY · COOL · HEAT · FAN Operation ............. 10 Adjusting the Airflow Direction ..... 12 COMFORT AIRFLOW Operation ....14 INTELLIGENT EYE Operation .....
  • Page 3: Safety Precautions

    • Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric shocks, fire etc. For repairs and reinstallation, consult your Daikin dealer for advice and information. • The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some reason any refrigerant happens to leak into the room, make sure it does not come in contact with any flame as of gas heaters, kerosene heaters or gas range.
  • Page 4: Installation Site

    • Do not block air inlets nor outlets. Impaired air flow may result in insufficient performance or trouble. • Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard. •...
  • Page 5: Names Of Parts

    Names of parts Indoor Unit...
  • Page 6: Indoor Unit

    Outdoor Unit 20/25/35/42 class 50 class Indoor Unit 1. Air filter 12. Indoor Unit ON/OFF switch: (page 10.) • Push this switch once to start operation. 2. Titanium Apatite Photocatalytic Push once again to stop it. Air-Purifying Filter: • The operation mode refers to the following •...
  • Page 7: Remote Controller

    Remote Controller ECONO ON/OFF TEMP POWERFUL MODE QUIET COMFORT SWING SENSOR CANCEL TIMER < > ARC433A85 1. Signal transmitter: 8. QUIET button: OUTDOOR UNIT QUIET operation (page 18.) • It sends signals to the indoor unit. 9. FAN setting button: 2.
  • Page 8: Preparation Before Operation

    Preparation Before Operation To set the batteries Position + and – correctly! 1. Slide the front cover to take it off. 2. Set two dry batteries AAA.LR03 (alkaline). 3. Set the front cover as before. ATTENTION About batteries • When replacing the batteries, use batteries of the same type, and replace the two old batteries together.
  • Page 9 Preparation Before Operation To operate the remote controller • To use the remote controller, aim the transmitter at the indoor unit. If there is anything to block signals between the unit and the remote control- ler, such as a curtain, the unit will not operate. •...
  • Page 10: Operation

    To set the clock 1. Press “CLOCK button”. is displayed. blinks. 2. Press “TIMER setting button” to set the clock to the present time. Holding down “ ” or “ ” button ECONO ON/OFF rapidly increases or decreases the time display.
  • Page 11: Auto · Dry · Cool · Heat · Fan Operation

    AUTO · DRY · COOL · HEAT · FAN Operation OPERATION The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. To start operation 1.
  • Page 12: To Change The Airflow Rate Setting

    To change the airflow rate setting 5. Press “FAN setting button”. DRY mode AUTO or COOL or HEAT or FAN mode Five levels of airflow rate setting from “ ” to “ ” plus “ ” “ ” are available. The airflow rate setting is not variable.
  • Page 13: Adjusting The Airflow Direction

    Adjusting the Airflow Direction You can adjust the airflow direction to increase your comfort. To adjust the horizontal blades (flaps) 1. Press “SWING button”. • “ ” is displayed on the LCD and the flaps will begin to swing. 2. When the flaps have reached the ECONO ON/OFF desired position, press “SWING...
  • Page 14 To start 3-D Airflow 1. 3. Press the “SWING button ” and the “SWING button ”: the “ ” and “ ” display will light up and the flap and louvers will move in turn. To cancel 3-D Airflow 2. 4. Press either the “SWING button ”...
  • Page 15: Comfort Airflow Operation

    COMFORT AIRFLOW Operation The flow of air will be in the upward direction while in cooling mode and in the downward direction while in heating mode, which will provide a comfortable wind that will not come in direct contact with people. To start COMFORT AIRFLOW operation 1.
  • Page 16: Intelligent Eye Operation

    INTELLIGENT EYE Operation “INTELLIGENT EYE” is the infrared sensor which detects the human movement. To start INTELLIGENT EYE operation 1. Press “COMFORT/SENSOR button” and select “ ” on the LCD. • Each time the “COMFORT/SENSOR button” is pressed a different setting option is displayed on the LCD.
  • Page 17 INTELLIGENT EYE Operation “INTELLIGENT EYE” is useful for Energy Saving Energy saving operation • Change the temperature –2°C in heating / +2°C in cooling / +2°C in dry mode from set temperature. • Decrease the airflow rate slightly in FAN mode only. If no presence detected in the room for 20 minutes.
  • Page 18: Powerful Operation

    POWERFUL Operation POWERFUL operation quickly maximizes the cooling (heating) effect in any operation mode. You can get the maximum capacity . To start POWERFUL operation 1. Press “POWERFUL button”. • POWERFUL operation ends in 20minutes. Then the system automatically operates ECONO ON/OFF again with the previous settings which were...
  • Page 19: Outdoor Unit Quiet Operation

    OUTDOOR UNIT QUIET Operation OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed on the outdoor unit. This function is convenient during night. To start OUTDOOR UNIT QUIET operation 1. Press “QUIET button”. •...
  • Page 20: Econo Operation

    ECONO Operation ECONO operation is a function which enables efficient operation by limiting the maximum power consumption value. To start ECONO operation 1. Press “ECONO button” . • “ ” is displayed on the LCD. To cancel ECONO 1, 2 ECONO ON/OFF operation...
  • Page 21: Timer Operation

    TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use OFF TIMER and ON TIMER in combination. To use OFF TIMER operation • Check that the clock is correct. If not, set the clock to the present time.
  • Page 22: To Use On Timer Operation

    To use ON TIMER operation • Check that the clock is correct. If not, set the clock to the present time. (page 9.) 1. Press “ON TIMER button”. is displayed. blinks. 2. Press “TIMER Setting button” until the time setting reaches the ECONO point you like.
  • Page 23: Note For Multi System

    Note for Multi System 〈〈 〉〉 What is a “Multi System”? This system has one outdoor unit connected to multiple indoor units. room Outdoor unit Selecting the Operation Mode room Living room 1. With the Priority Room Setting present but inactive or not present. room When more than one indoor unit is operating, priority is given to the first unit that was turned on.
  • Page 24 Priority Room Setting The Priority Room Setting requires initial programming during installation. Please consult your retailer or dealer for assistance. The room designated as the Priority Room takes priority in the following situations; 1. Operation Mode Priority. As the operation mode of the Priority Room takes precedence, the user can select a different operation mode from other rooms.
  • Page 25: Care And Cleaning

    Care and Cleaning CARE CAUTION Before cleaning, be sure to stop the operation and turn the breaker OFF. Units Indoor unit, Outdoor unit and Remote controller 1. Wipe them with dry soft cloth. Front panel 1. Open the front panel. •...
  • Page 26: Air Filter

    Filters 1. Open the front panel. (page 24.) 2. Pull out the air filters. • Push a little upwards the tab at the center of each air filter, then pull it down. 3. Take off the Titanium Apatite Photocatalytic Air-Purifying Filter. •...
  • Page 27: Before A Long Idle Period

    NOTE • Operation with dirty filters: (1) cannot deodorize the air. (2) cannot clean the air. (3) results in poor heating or cooling. (4) may cause odour. • To order Titanium Apatite Photocatalytic Air-Purifying Filter contact to the service shop there you bought the air conditioner.
  • Page 28: Trouble Shooting

    Trouble Shooting TROUBLE SHOOTING These cases are not troubles. The following cases are not air conditioner troubles but have some reasons. You may just continue using it. Case Explanation Operation does not start soon. • This is to protect the air conditioner. •...
  • Page 29: Check Again

    Check again. Please check again before calling a repair person. Case Check The air conditioner does not • Hasn’t a breaker turned OFF or a fuse blown? operate. • Isn’t it a power failure? (OPERATION lamp is off.) • Are batteries set in the remote controller? •...
  • Page 30: Call The Service Shop Immediately

    Call the service shop immediately. WARNING ■ When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF. Continued operation in an abnormal condition may result in troubles, electric shocks or fire. Consult the service shop where you bought the air conditioner. ■...
  • Page 31: Fault Diagnosis

    Fault diagnosis. FAULT DIAGNOSIS BY REMOTE CONTROLLER In the ARC433 series, the temperature display sections on the main unit indicate corresponding codes. 1. When the TIMER CANCEL button is held down for 5 seconds, a “ ” indication flashes on the temperature display section.
  • Page 32 LED ON OUTDOOR UNIT PCB 2AMX, 3AMX series GREEN MICROCOMPUTER MALFUNCTION NORMAL DETECTION DIAGNOSIS LED-A LED1 LED2 LED3 LED4 NORMAL CHECK INDOOR UNIT HIGH PRESSURE PROTECTOR WORKED OR FREEZE-UP IN OPERATING UNIT OR STAND-BY UNIT ∗ OVERLOAD RELAY WORKED OR HIGH DISCHARGE PIPE TEMPERATURE FAULTY COMPRESSOR START INPUT OVERCURRENT ∗...
  • Page 33 MEMO...
  • Page 34 Two-dimensional bar code is a code for manufacturing. 3P207037-2D M07B015B (0903) HT...

Table of Contents