Parameter overview
Parameter
Func-
Name
tion
Terminal 2 frequency
125
setting gain frequency
Terminal 4 frequency
126
setting gain frequency
Analog input display
241
unit switch over
Terminal 2 frequency
C2
(902)
setting bias frequency
Terminal 2 frequency
C3
(902)
setting bias
Terminal 2 frequency
C4
(903)
setting gain
Terminal 4 frequency
C5
(904)
setting bias frequency
Terminal 4 frequency
C6
(904)
setting bias
Terminal 4 frequency
C7
(905)
setting gain
Tab. 6-1:
Parameter overview (18)
6 - 18
Incre-
Initial
Setting
ments
value
range
0.01Hz
50Hz
0–400Hz
0.01Hz
50Hz
0–400Hz
0
1
0
1
0.01Hz
0Hz
0–400Hz
0.1%
0%
0–300%
0.1%
100%
0–300%
0.01Hz
0Hz
0–400Hz
0.1%
20%
0–300%
0.1%
100%
0–300%
Description
Set the frequency of terminal 2
input gain (maximum).
Set the frequency of terminal 4
input gain (maximum).
Displayed in
Select the unit for
%
analog input dis-
Displayed in
play.
V/mA
Set the frequency on the bias side
of terminal 2 input.
Set the converted % of the bias
side voltage (current) of terminal 2
input.
Set the converted % of the gain
side voltage of terminal 2 input.
Set the frequency on the bias side
of terminal 4 input.
Set the converted % of the bias
side current (voltage) of terminal 4
input.
Set the converted % of the gain
side current (voltage) of terminal 4
input.
Parameter
All
Para-
Para-
Para-
meter
meter
meter
copy
clear
clear
Refer
to
page
✔: enabled
—: disabled
✔
✔
—
✔
✔
—
✔
✔
✔
✔
✔
—
✔
✔
6-180
—
✔
✔
—
✔
✔
—
✔
✔
—
✔
✔
—